STEP THREE:
Clean the Tank
1
STEP FOUR:
Replace the Water Level Sensor (if necessary)
WARNING: Electrocution Hazard.
Steam Humidifier must be unplugged before removing the cover. Hazardous voltage could
cause death or serious injury.
2
5
Steam Humidifier System 69-2285—09
Use tap water to flush loose minerals from the tank:
Sediment screen at tank's bottom is removable.
For a more thorough cleaning, soak tank in water
with CLR
rinse clean.
Tank is dishwasher safe.
Do not use hydrocarbon-based cleaners.
Unplug the power cord and carefully rub minerals off of
the heating element and tank walls. Clear the sensor
compartment holes of debris, if present.
2
MCR29631
Remove Steam Humidifier cover and inspect water
level sensor. If debris buildup is present, clean with
recommended cleaning agent. If cracks or visible
1
discoloration is noticed, replace sensor (see below).
Remove T-30 Torx screw and lift clamp.
Remove the sensor.
3
Ensure sensor gaskets are seated properly and are
4
in good condition (no cracks). If cracks are noticed,
replace water sensor assembly (including gaskets).
Install a new sensor if excessive mineral deposits are
MCR29632
present, or if gaskets are in poor condition. See "Parts
List" on page 66.
, LimeAway
or white vinegar. Then
®
®