Eeprom Initialization; Transferring Calibration Constants To Factory Preset Locations - Agilent Technologies 6571A Service Manual

Gpib dc power supplies series 657xa and 667xa
Table of Contents

Advertisement

EEPROM Initialization

EEPROM AlU6 on the A1 Front Panel Board stores the supply's GPIB address, model number, and constants required to
program and calibrate the power supply. If either the front panel board or the EEPROM is replaced, the power supply must
be reinitialized with the proper constants by running the program listed in Figure 3-18.
When the program pauses and asks you to make a selection, respond as follows:
Initialization (I) or Factory Preset Replacement (F)? I
After the power supply has been initialized, it must be calibrated as described in Appendix A of the Operating Manual.
After calibration, transfer the new calibration constants to the EEPROM's "Factory Cal" locations as described next.

Transferring Calibration Constants To Factory Preset Locations

A newly initialized and calibrated power supply has calibration constants in operating locations but does not have the new
factory calibration constants stored in EEPROM. This procedure transfers the calibration constants into the EEPROM
FACTORY PRESET CAL locations by running the program listed in Figure 3-18.
When the initialization program pauses and asks you to make a selection, respond as follows:
Initialization (I) or Factory Preset Replacement (F)? F
The new calibration constants will then be stored. Pre-initialized and tested A1 Front Panel boards are available for Analog
Programmable "bench" series supplies. (see Chapter 5, Table 5-4 for part numbers.)
A Bench Series Supply can be initialized and the new Factory Preset calibration constants loaded by temporarily replacing
the A2 Isolator board with an A2 GPIB board. Then follow the instructions above for "EEPROM INITIALIZATION" and
also "TRANSFERRING CALIBRATION CONSTANTS TO THE FACTORY PRESET LOCATIONS" described above.
After the supply has been Initialized, Calibrated, and the new Factory Presets stored, remove the GPIB board and reinstall
the original Isolator board.
10
! Program to initialize EPROM or move factory preset data in 657xA
20
!
and 667xA power supplies.
30
!
RE-STORE " INIT_2KW"
40
!
Rev A.00.00 dated June 28, 1993
50
!
60
DIM Init_data(1:45),Model$[5],Idn$[21],Cal_data$[40]
70
INTEGER Addr(1:45),Length(1:45)
80
ASSIGN @Ps TO 705
90
CLEAR SCREEN
100
!
110 Eprom_data_addr:
120
DATA 2,6,10,14,18,19,20,24,28,32
130
DATA 36,37,38,42,46,50,54,55,56,57
140
DATA 64,68,72,76,80,150,l52,153,154,155
Figure 3-18. Initialization and Factory Preset Replacement Program Listing (Sheet 1 of 6)