DLT-U1100 UPS
Uninterruptible Power Supply
Manual V1.00

Advertisement

Table of Contents
loading

Summary of Contents for Advantech DLT-U1100

  • Page 1 Industrial PCs applied in Logistics and Warehouse Heavy Duty Fleet Management Stationary and Automation DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00...
  • Page 2 This documentation is protected by copyright. Duplication, in whole or in part, is not permitted without prior written approval of DLoG GmbH. Manual title: Manual DLT-U1100 External Uninterruptible Power Supply (UPS) for MTC 6 and XMT 5 Industrial PCs (12/24 VDC)
  • Page 3: Table Of Contents

    2.2. Always mount, operate and service the device correctly ...................... 8     2.3.   Industrial PCs approved for UPS DLT-U1100 ........................8   2.4.   No combination of UPS + automatic start/shut down via ignition possible ................9  ...
  • Page 5: Available Manuals For Ups Dlt-U1100

    Unauthorized persons must be kept away from the UPS which contains rechargeable Lithium Ion batteries. If the DLT-U1100 is incorrectly installed and configured, the DLoG GmbH warranty for this device will be canceled. DLoG GmbH assumes no liability for damages caused directly or indirectly by the incorrect installation or usage of the DLT-U1100.
  • Page 6: Design Method In This Manual

    Available Manuals for UPS DLT-U1100 1.4. Design method in this manual The following icons are used in this manual to indicate dangers, notices etc.: Personal injury The following levels apply, denoted by the respective keyword: DANGER: There is an immediate risk of death / serious injury...
  • Page 7: Basic Safety Guidelines

    The DLT-U1100 is a battery-operated uninterruptible power supply for the Advantech-DLoG industrial PCs MTC 6 and XMT 5, each with 12/24 VDC power supply unit. Any other or additional use is not as intended. The user/operator of the DLT-U1100 is solely responsible for any resulting damage.
  • Page 8: Always Mount, Operate And Service The Device Correctly

    The DLT-U1100 was designed and built according to modern technology and accepted safety regulations. However, the operation of the DLT-U1100 can endanger personnel or third parties and cause damage to the device and other material assets when for example the device is −...
  • Page 9: No Combination Of Ups + Automatic Start/Shut Down Via Ignition Possible

    PC via the <POWER> button or the vehicle’s ignition. Please take into consideration: If the DLT-U1100 is connected, the industrial PCs MTC 6 and XMT 5 cannot be started or shut down automatically via vehicle ignition.
  • Page 10: Mounting The Dlt-U1100

    Do not perform any repairs. Repairs on the DLT-U1100 may be made only by Service Centers authorized by Advantech-DLoG. Do not submerge the DLT-U1100 and cables in water or other liquids because of the danger of electrical shock. Use only original power cables by Advantech-DLoG; they meet special requirements for low-temperature flexibility, UV resistance, oil resistance, etc.
  • Page 11: Technical Specifications

    Technical specifications 3. Technical specifications 3.1. Warranty DLT-U1100 devices DLT-U1100 devices (batteries excluded) are warranted as specified in Advantech-DLoG (batteries excluded) TOB (http://www.dlog.com/en/tob/). Batteries Batteries are warranted for a period of six (6) months from delivery. 3.2. System Bridging time...
  • Page 12: Environment

    EN 61000-4-3: 2006 + A1:2008 + A2:2010 EN 61000-4-4:2012 EN 61000-4-5:2006 EN 61000-4-6:2009 EN 61000-4-8:2010 EMC emissions EN61000-6-4:2007 + A1:2011 EN 55011: 2009 + A1:2010 CE-marking 3.5. Approvals batteries UN 38.3 EN 62133 Page 12 of 26 DLT-U1100 Manual V1.00 Advantech-DLoG...
  • Page 13: Dlt-U1100 Dimensions

    Technical specifications 3.6. DLT-U1100 dimensions Dimensions in mm: Figure 3.1: Dimensions DLT-U1100 top view Figure 3.2: Dimensions DLT-U1100 side view Advantech-DLoG DLT-U1100 Manual V1.00 Page 13 of 26...
  • Page 14: Mounting Brackets With Drill Holes

    Dimensions in mm: Mounting bracket with 2 drill holes for M3.5x6 mm threaded screws Mounting bracket with 2 drill holes for M3.5x6 mm threaded screws Figure 3.3: Two mounting brackets with drill holes Page 14 of 26 DLT-U1100 Manual V1.00 Advantech-DLoG...
  • Page 15: Unpacking The Dlt-U1100

    Connecting wires for power source on the vehicle 4.2. Packaging / Returning your device Save the packaging material for possible forwarding transports or returns of the DLT-U1100. When returning the device, use the Return shipment form at the end of the manual.
  • Page 16: Mounting The Dlt-U1100

    Do not perform any repairs. Repairs on the DLT-U1100 may be made only by Service Centers authorized by Advantech-DLoG. Do not submerge the DLT-U1100 and cables in water or other liquids because of the danger of electrical shock. Use only original power cables by Advantech-DLoG; they meet special requirements for low-temperature flexibility, UV resistance, oil resistance, etc.
  • Page 17: Check Automatic Switch-Off Settings

    The electrical connection point suitable for the DLT-U1100 depends on the respective vehicle type. − Make sure to observe the technical/electrical information of the vehicle manufacturer. − Keep in mind that certain electrical connection points are not suitable for the DLT-U1100, e.g. for vehicles with braking energy reclamation.
  • Page 18: Mounting Steps

    − With some vehicles, the chassis represents DC+. The DLT-U1100 chassis is then also DC+. If peripheral devices now supply DC-, e.g. via a plug connector through a serial interface to the shield connection of the DLT-U1100, a short circuit is inevitable and malfunctions/total failures are unavoidable.
  • Page 19: Procedure

    M3.5x6 mm threaded screws. Connect the connection cable to the electrical connection point of the vehicle. Connect with the DLT-U1100 (input) as shown in position (6). Connect connection cable to the industrial PC: For this purpose, plug the Phoenix contact plug into the UPS connection of the industrial PC and screw tight.
  • Page 20: Power Supply Cable (Detail View)

    Figure 5.3: Power supply cable CAUTION: Hazardous voltage, electric shock Use only original power supply cables from Advantech-DLoG. Advantech-DLoG power cables meet the specific requirements for low-temperature flexibility, UV resistance, oil resistance, etc. If other power supply cables are used: −...
  • Page 21: Cleaning The Dlt-U1100

    6. Cleaning the DLT-U1100 WARNING: Danger due to electric shock when cleaning the device To avoid electric shock, turn the DLT-U1100 off and disconnect it from the power supply before cleaning it. Servicing permitted only through skilled electronics persons. Turn off the DLT-U1100.
  • Page 22: Reasonably Forseeable Misuse

    Reasonably forseeable misuse 7. Reasonably forseeable misuse The UPS DLT-U1100 can only supply the following devices with power: − MTC 6 Series Industrial PCs with 12/24 VDC power supply unit − XMT 5 Series Industrial PCs with 12/24 VDC power supply unit The UPS DLT-U1100 has been designed for this supply voltage.
  • Page 23: Technical Customer Support

    If you experience technical difficulties, please consult your distributor or contact the technical services department at Advantech-DLoG’s headquarters: Phone: (+49) 89 / 41 11 91 0 E-Mail: service@dlog.com Supplier address: DLoG GmbH Industriestraße 15 D-82110 Germering Internet: www.advantech-dlog.com E-Mail: info@dlog.com Advantech-DLoG DLT-U1100 Manual V1.00 Page 23 of 26...
  • Page 24: End-Of-Life Device Disposal

    End-of-life electrical devices must be recycled and may not disposed of with general/domestic waste. Contact an approved certified electrical scrap-recycling company for proper disposal. Used batteries may also not be disposed of with general/domestic waste. Page 24 of 26 DLT-U1100 Manual V1.00 Advantech-DLoG...
  • Page 25: Return Shipment Form

    [ ] Unit was already damaged on delivery (please enclose a copy of the delivery note) [ ] Delivery was incomplete Missing parts: [ ] The following error occurs when operating the unit: [ ] Separate error report is enclosed. Advantech-DLoG DLT-U1100 Manual V1.00 Page 25 of 26...
  • Page 26: List Of Figures

    List of figures 11. List of figures Figure 2.1: UPS DLT-U1100 ..................................... 7   Figure 2.2: Application example DLT-U1100 and MTC 6 ..........................8   Figure 3.1: Dimensions DLT-U1100 top view ..............................13   Figure 3.2: Dimensions DLT-U1100 side view ..............................13  ...