Technical Data - Firefly CYG/12/36 User Manual

Cygnus hybrid power generator 12-24
Table of Contents

Advertisement

4.3   Technical Data
Model
Continuous Output @ 25°c
Peak Power Output @ 25°c (30 minutes)
Peak Power Output @ 25°c (5 seconds)
AC Output Voltage (50 Hz)
AC Input Current Max
AC Output Current Max
Transfer Relay Time
Standby Power Consumption
Inverter Protection
Battery Storage Type
Battery Capacity
Earth Fault Protection
Power Input Connections
Power Output Connections
Auxiliary Connection (Remote generator Start)
Battery Monitoring
Available Menu Languages
Charge Time (Using 63 A 3P Inlet)
Set up time
Water/Ingress Protection Rating
Operating Temperature Range
Weight
Dimensions (W x D x H)
Packaged Dimensions (W x D x H)
Fork Pocket Dimensions (W x D x H)
Distance Between Fork Pockets (W)
Battery Upgrade Package*
Solar Preparation Upgrade Package*
Remote communication and data collection package*
* Optional upgrades available pre or post purchase of main unit.
** kWh ratings based on C20 battery ratings and 60% DoD (Depth of Discharge). Depth of discharge set at factory to
ensure life cycle of battery bank. Adjustable if required.
Page 30
CYGHPG-User-Manual-v2
Cygnus HPG Technical data
CYG/12/36
10.5 kVA
12.0 kVA
31.5 kVA
6.2 W
Overload, Overheat, Short Circuit, Low Battery, Excess Battery Voltage Ripple
1 x 63 A 240 V SP CEE Form, 1 x 63 A 400 V 3P+N+E CEE Form
1 x 63 A 240 V SP CEE Form, 1 x 63 A 400 V 3P+N+E CEE Form, 63 A 240 V/400 V bus bar connection
Bulgin Buccaneer Mini400 4 pin 9 / bus bar mounted screw terminal contacts
(Voltage, Power In/Out, % Capacity Available, Time Available, State of Charge History)
2250 kg (2700 kg with Battery Upgrade Package)
MPPT controller with up to 5 kWp array connection
Integrated GSM Modem & GPS allowing collection of system status, live data,
historic data, fault & event notification, location data, external device data and
control, system control and programming.
CYG/18/36
15.0 kVA
18.0 kVA
45.0 kVA
190-245 V / 415 V
63 A 3 Phase
63 A 3 phase with external AC source connected
<15 ms (seamless)
6.6 W
AGM Sealed
36 kWh**
63 A 1 pole 100 mA RCD, 63 A 3 pole 100 mA RCD
(2 programmable Aux. relays)
LCD Battery Monitor
English, French, Spanish, German
7.5 hrs
5 minutes
IP44
-5°c to +45°c
1200 mm x 2000 mm x 1300 mm
1306 mm x 2106 mm x 1512 mm
1100 mm x 190 mm x 100 mm
81 0 mm
12 kWh additional storage**
CYG/24/36
21.0 kVA
24.0 kVA
63.0 kVA
7.2 W

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents