Measurements And Adjustments; Adjustment Procedure - Panasonic TH-42PH11UK Service Manual

High definition plasma display gph11d chassis
Table of Contents

Advertisement

9 Measurements and Adjustments

9.1.

Adjustment Procedure

9.1.1.
Driver Set-up
9.1.1.1.
Item / Preparation
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
Caution
1. First perform Vsus adjustment.
2. Confirmation of Vscn voltage should be performed after
confirmation of Vad adjustment.
When Vad=-149V, Voltage of Vscn is -4V ±4V.
9.1.1.2.
Adjustments
Adjust driver section voltages. (Refer to the panel data on the
Panel Label).
Check or adjust the following voltages with the multimeter.
Name
Test Point
Voltage
Vsus
TPVSUS
Vsus ± 2V
(SS)
Ve
TPVE (SS)
Ve ± 1V
Vset
TPVSET
320V + 7V, -
(SC)
9V
Vad
TPVAD (SC) -149V ± 1V
Vscn
TPVSCN
Vad+145V ±
(SC)
4V
Vda
TPVDA (SS) 75V + 1V, -2V Fixed
PFC
C446 (+)(-)
396V ± 0.5V
*See the Panel Label.
29
TH-42PH11UK
Volume
Remarks
R628 (P)
*
VR16000
*
(SS)
Fixed
VR16600
(SC)
Fixed
R443 (P)

Hide quick links: