8.4 Failure Analysis Process:
Fault self-test code: 3
Evaporator freezing
Evaporator freezing?
yes
Compressor stop?
no
Turn off the power and open
air-conditioners after
defrosting on the evaporato
Continue to freeze?
yes
Turn off power, and open air-
conditioners after replacing
the outdoor control board
Air-conditioner is
normal?
no
Indoor control board fault and
replace it
Evaporation
no
temperature sensor
fault
Normal protection
yes
action
r
Unexpected
no
phenomenon
Outdoor control board
yes
fault
Page 32 of 37
Fault self-test code: 4
Evaporation overload
evaporator with high-
temperature?
yes
Compressor stop?
no
Turn off the power and open
air-conditioners after 10
minutes
Air-conditioner is
normal?
no
Turn off power, and open air-
conditioners after replacing
the outdoor control board
Air-conditioner is
normal?
no
Indoor control board fault and
replace it
Evaporation
no
temperature sensor
fault
Normal protection
yes
action
Unexpected
yes
phenomenon
Outdoor control board
yes
fault

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

88fzbpcKfr-72lw/88fzbpc

Table of Contents