Demand Control - Panasonic CS-RE18PKR Service Manual

Hide thumbs Also See for CS-RE18PKR:
Table of Contents

Advertisement

13.3.7

Demand Control

When the air-conditioner connected to Demand Response Enabling Devices (DRED), the power consumption
especially during peak hours could be controlled.
Three Demand response modes (DRM) are available
DRM1 = Compressor cut off
o
DRM2 = Operate at 50% of rated input power
o
DRM3 = Operate at 75% of rated input power
o
During DRM1, the Power Indicator blinks (3 seconds ON and 0.5 seconds OFF) to indicate the compressor cut
off status.
13.3.8
Pump down Operation by CN-S
A convenience method to activate pump down operation.
Control start condition:
During power standby condition, short CN-S continuously between 1 second and 10 seconds.
o
Control stop condition:
480 seconds after pump down operation starts.
o
CN-S is shorted again during pump down operation.
o
62

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-re24pkrCu-re18pkrCu-re24pkrCu-re28pkrCs-re28pkr

Table of Contents