The INPUT SETTING Menu
Input signals and adjustable/setting items
Item
Video or
15k
S video
RGB
DOT PHASE
N
N
SIZE
N
N
SHIFT
Y
Y
SCAN CONV
N
N
ASPECT
Y
Y
H FILTER
N
N
BLANKING
Y
Y
(TOP
(TOP and
and
BOTTOM
BOTTOM
only)
only)
Y: Adjustable/can be set
N: Not adjustable/cannot be set
INPUT MEMORY No.
The upper number indicates the memory number of the
current input signal. The lower number indicates the
user memory number.
INPUT SETTING
INPUT-A
DOT PHASE:
8
SIZE
H:1 0 4 8
SHIFT
H:1 2 3 V: 1 2 3
1024x768
N O .
n
24
(GB)
Input signal
Component/
RGB
RGB
Progressive
(preset)
(not preset)
component
N
Y
Y
(except
for
HDTV,
DTV)
Y
Y
Y
Y
Y
Y
N
Y
Y
(Only for
(Only for
lower
lower
resolution
resolution
than
than SXGA)
SXGA)
Y
N
N
N
Y
Y
(UXGA
(UXGA only)
only)
Y
Y
Y
(TOP
(HDTV,
and
DTV
BOTTOM
only)
only)
Type of input signal
Memory number
1
2 3
User memory
number
About the memory function
The adjustment data for 48 types of input signals are
preset at the factory (preset memory).
When a signal is input to the projector, the signal type
is automatimally detected and the data for the signal is
called from the memory to display an optimum picture.
The data can be adjusted in the INPUT SETTING
menu and the adjusted data will be saved as user
memory.
When you save more than 200 user memories, the
newest one always overwrites the oldest one.
The saved user memory number is displayed in the
INPUT SETTING menu as n NO. ππ.
When an RGB signal other than the preset signals is
input to the projector, the memory number is displayed
as 0 and the closest option is automatically selected
from the preset 48 types of signals.
Notes
• When an RGB signal is input with sync on Green
including external sync, the picture tone may be
greenish. In this case, disconnect the external sync
signal.
• When an HDTV 1035/60i signal is input, the picture
will appear smaller. Adjust SIZE, SHIFT and
BLANKING referring to the following levels as a
standard.
SIZE
H: 1479
SHIFT
H: 321
V: 41
BLANKING TOP: 167
BOTTOM: 167
RIGHT: 27
LEFT: 27
• If SCAN CONV is set to ON when a signal in
Memory No. 34 –38 is input, the picture will appear
widened. Adjust SIZE and SHIFT, referring to the
following levels as a standard.
Memory No.
34
SIZE
1590
H
181
SHIFT
V
18
35
36
37
1575
1590
1582
1620
170
182
146
154
32
36
36
38
42