Communications Settings; Testing For Current Settings - GE Interlogix 840 Installation Manual

Contactless smart card reader
Table of Contents

Advertisement

Communications Settings

Testing for Current Settings

Perform the following steps to test for current settings:
NOTE: RS-232 mode for Revision B printed circuit boards and higher.
1.
Remove power from the reader.
2.
Place a mini-jump over both pins of JP4.
3.
Add power to the reader and listen for the number of beeps.
NOTE: The number of beeps indicate the current communications mode
set.
1 beep = Supervised F/2F
2 beeps = Unsupervised F/2F
3 beeps = Strobe
4 beeps = Wiegand 4001
5 beeps = RS-232
4.
Remove power from the reader.
5.
Place a mini-jump over one (1) pin of JP4.
6.
Add power to the reader and resume normal operations.