Guardian Telecom Inc.
If Pulse dialing is required refer to the Maintenance section
Follow all appropriate electrical codes and use only approved electrical
fittings for the installation.
Choose a wall location that is free of obstructions and permits space for
wiring or ½" NPT conduit runs if required.
Ensure mounting can support 4lbs (1.8kg) and any additional foreseeable
load.
Ensure that none of the electrical connection circuits are live.
Use the template provided to locate and drill holes for #10 or M5 mounting
screws.
Remove the eight #10 Philips drive faceplate screws, remove the faceplate
and unplug the harness.
Secure the unit to the wall.
For Model P6260 (with a 7/8" entry hole): install a suitable grommet or hub
and bring cable into the enclosure through the entrance. Attach individual
wires from the exchange (Tip/Ring/Ground) to the terminal strip (Tip & Ring
are not polarity sensitive). If a conduit hub is used, ensure it is grounded to
the ground stud.
For Model P6264 (with a ½" conduit hub): bring cable into the enclosure
through the conduit entrance and attach individual wires from the exchange
(Tip/Ring/Ground) to the terminal strip (Tip & Ring are not polarity
sensitive.). Ensure that the conduit hub is grounded to the ground stud.
Reconnect the harness, ensure all connections are tight, then replace the
faceplate and secure with eight #10 Philips drive screws.
Apply power to the system.
Test the unit by calling to and from another unit on the exchange.

Installing the HR60

Page 5
Installation and Operation
Model HR60
See: Figure 3 - Internal
Layout
See: Figure 1 - Mounting
Note: Be careful when
removing the faceplate,
the circuit board is on the
faceplate.
Tip: Use #10 or M5
screws to secure the unit
to the wall.
See: Figure 3 - Internal
Layout