Guardian Telecom Inc
Follow all appropriate electrical codes and use only approved electrical
fittings for the installation.
To change the Tone/Pulse setting to pulse, if required:
o Remove the four top screws and carefully remove the cover.
o Move the jumper from pins 1 & 2 of the Tone/Pulse connector to
pins 2 & 3.
o To change the setting back to tone move the jumper back to
pins 1 & 2.
o Replace the cover and the four screws.
Note: The model DTT can be either desk mounted or wall mounted.
If the DTT is to be desk mounted simply place it in the desired location.
If the DTT is to be wall mounted follow these instructions.
o Remove the four top screws and carefully remove the cover.
o Disconnect the harness plugs and set the cover aside.
o Using a flat screwdriver or similar instrument carefully pry the chassis
away from the base at the four corners.
o Loosen the locknut on the forty-five degree cable gland, rotate the
gland 180 degrees and re-fasten the locknut.
o Secure the base to the wall at the desired location.
o Rotate the chassis 180 degrees from the original orientation and snap
it back into the base.
o Rotate the cover 180 degrees from the original orientation and
reconnect the harness plugs.
o Replace the cover and the four screws.
Ensure that none of the electrical connection circuits are live.
Connect the Tip, Ring and Ground conductors in the cable provided to the
telephone line at a junction box.
Test the unit by calling to and from another unit on the exchange.

Installing the DTT Telephone

Installation and Operation
Page 6
Model DTT
See: Government
Certification.
Tip: The DTT is factory
preset for DTMF tone.
See: Figure 2 - Wall
Mounting
See: Figure 3 - Internal
Wiring
See: Figure 4 -
Mechanical Assembly
Note: Tip and Ring are
not polarity sensitive.

Advertisement

Table of Contents
loading

Table of Contents