Guardian Telecom Inc.
•
Follow all appropriate electrical codes and use only approved electrical
fittings for the installation.
•
For waterproofing purposes apply Teflon tape to all glands and conduits.
•
Choose a wall location that is free of obstructions and permits space for ½"
NPT conduit runs.
•
Ensure mounting can support 16 lbs (7.3 kg) and any additional foreseeable
load.
•
Ensure that none of the electrical connection circuits are live.
•
Separate the faceplate from the housing by removing the two temporary,
factory installed screws and unplugging the wiring harness from the
faceplate.
•
To change the Tone/Pulse setting to pulse, if required:
o Move the jumper from pins 1 & 2 of the Tone/Pulse connector to
pins 2 & 3.
o To change the setting back to tone move the jumper back to pins 1 & 2.
•
Use the template provided or the mounting bracket to locate and drill holes
for mounting screws.
•
Secure the unit to the wall.
•
Bring cable into the enclosure through the conduit entrance and attach
individual wires from the exchange (Tip/Ring/Ground) to the surge arrestor,
(Tip & Ring are not polarity sensitive.). If a conduit hub is used, ensure it is
grounded to the ground stud.
•
Plug the wiring harness back into the faceplate and secure the faceplate
using the tamper resistant screws and driver bit provided.
•
Connect the telephone lines at the local exchange or demarcation block.
•
Test the unit by making calls to and from another station.
Installing the WP80
TONE/PULSE
JUMPER
Guardian Telecom Inc.
S/N:____________
Calgary, Canada
PHONE
RIN-
HK
TONE/
HANDSET
LINE
GER
SW
PULSE
Figure 3 - Setting Dialing Mode
Page 5
Installation and Operation
Model WP80
See: Figure 1 - Overall
Dimensions.
Tip: The WP80 is factory
preset for DTMF tone.
See:.Figure 3 - Setting
Dialing Mode
Tip: Use ¼" or M8
screws to secure the unit
to the wall.
See: Figure 2 -