Fan Speed Control - Asus MAXIMUS VII GENE User Manual

Table of Contents

Advertisement

Fan Speed Control

CPU Q-Fan Control [Auto]
[Auto]
Detects the type of CPU fan installed and automatically switches the
mode control. When a 3-pin CPU fan is installed, select this mode for the
DC mode Q-Fan control.
[DC Mode]
Enables the CPU Q-Fan control feature in DC mode for 3-pin CPU fan.
[PWM Mode]
Enables the CPU Q-Fan control feature in PWM mode for 4-pin CPU fan.
The following items appear only when you set the CPU Q-Fan Control to [Auto].
CPU Fan Speed Lower Limit [300 RPM]
This item allows you to set the low limit warning for CPU Fan speed.
Configuration options: [Ignore] [200 RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM]
CPU Fan Profile [Standard]
This item allows you to set the appropriate performance level of the CPU fan.
[Standard]
Set to make the CPU fan adjust automatically depending on the CPU
temperature.
[Silent]
Set to minimize the fan speed for quiet CPU fan operation.
[Turbo]
Set to achieve maximum CPU fan speed.
[Manual]
Set to assign the detailed fan speed control parameters.
The following items appear only when you set the CPU Fan Profile to [Manual].
CPU Upper Temperature [70]
Use the <+> or <-> keys to adjust the upper limit of the CPU temperature.
The values range from 20ºC to 75ºC.
CPU Fan Max. Duty Cycle (%) [100]
Use the <+> or <-> keys to adjust the maximum CPU fan duty cycle. The
values range from 20% to 100%. When the CPU temperature reaches the
upper limit, the CPU fan will operate at the maximum duty cycle.
CPU Middle Temperature [45]
Displays the lower limit of the CPU temperature.
CPU Fan Middle. Duty Cycle (%) [60]
Use the <+> or <-> keys to adjust the maximum CPU fan duty cycle. The
values range from 20% to 100%. When the CPU temperature reaches the
upper limit, the CPU fan will operate at the maximum duty cycle.
CPU Lower Temperature [40]
Displays the lower limit of the CPU temperature.
CPU Fan Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum CPU fan duty cycle. The
values range from 0% to 100%. When the CPU temperature is under 40ºC,
the CPU fan will operate at the minimum duty cycle.
Chassis Fan 1/2/3 Q-Fan Control [DC Mode]
[Disabled]
Disables the Chassis Q-Fan control feature.
[DC mode]
Enable the chassis Q-Fan control in DC mode for 3-pin chassis fan.
[PWM mode]
Enable the chassis Q-Fan control in PWM mode for 4-pin chassis fan.