Toshiba RAS-B10GKVP-E Installation Manual

Toshiba RAS-B10GKVP-E Installation Manual

Split type for general public use
Hide thumbs Also See for RAS-B10GKVP-E:

Advertisement

AIR
CONDITIONER
CLIMATISEUR (TYPE SEPARE)
KLIMAGERÄT (GETEILTE AUSFÜHRUNG)
CONDIZIONATORE D'ARIA (TIPO SPLIT)
ACONDICIONADOR DE AIRE (TIPO SEPARADO)
ΚΛΙΜΑΤΙΣΤΙΚΗ ΜΟΝΑ∆Α (∆ΙΑΙΡΟΥΜΕΝΟΥ ΤΥΠΟΥ)
AR CONDICIONADO (TIPO SPLIT)
LUFTKONDITIONERING (SPLITTYP)
КОНДИЦИОНЕР (РАЗДЕЛИТЕЛЬНЫЙ ТИП)
nchasing this TOSHIBA Air Conditioner. Please read this owner's manual carefully before using your Air Conr.
Please read this installation manual carefully before installing the air conditioner.
Veuillez lire attentivement ce manuel avant d'installer le climatiseur.
Lesen Sie diese Einbauanleitung sorgfältig durch, bevor Sie das Klimagerät installieren.
Prima di installare il condizionatore d'aria, si consiglia di leggere con attenzione il presente manuale di installazione.
Lea este manual de instalación atentamente antes de instalar el acondicionador de aire.
Παρακαλούµε διαβάστε αυτές τις οδηγίες εγκατάστασης προσεκτικά πριν εγκαταστήσετε την
κλιµατιστική µονάδα.
Leia atentamente este manual de instalação antes de instalar o ar condicionado.
Läs den här installationsanvisningen noga innan du installerar luftkonditioneringen.
Перед установкой кондиционера прочитайте, пожалуйста, внимательно эту инструкцию по
установке.

INSTALLATION MANUAL

MANUEL D'INSTALLATION
EINBAUANLEITUNG
MANUALE DI INSTALLAZIONE
MANUAL DE INSTALACIÓN
Ο∆ΗΓΙΕΣ ΕΓΚΑΤΑΣΤΑΣΗΣ
MANUAL DE INSTALAÇÃO
INSTALLATIONSANVISNING
ИНСТРУКЦИЯ ПО УСТАНОВКЕ
(SPLIT TYPE)
For general public use
Pour utilisation grand public
Für allgemeine Verwendung
Per l'uso in generale
Para el uso público general
Για γενική δηµόσια χρήση
Para utilização geral
För allmän användning
Для общего бытового использования
Indoor Unit
Unité intérieure
Innenraumgerät
Unità interna
Unidad interior
Εσωτερική µονάδα
Unidade interior
Innedel
Внутренний блок
RAS-B10GKVP-E
RAS-B13GKVP-E
RAS-B16GKVP-E
RAS-M10GKCVP-E
RAS-M13GKCVP-E
RAS-M16GKCVP-E
Outdoor Unit
Unité extérieure
Außengerät
Unità esterna
Unidad exterior
Εξωτερική µονάδα
Unidade exterior
Utedel
Наружный блок
RAS-10GAVP-E
RAS-13GAVP-E
RAS-16GAVP-E
RAS-M14GAV-E
RAS-M18GAV-E
RAS-M14GACV-E
RAS-M18GACV-E

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAS-B10GKVP-E

  • Page 1: Installation Manual

    RAS-M13GKCVP-E RAS-M18GACV-E RAS-M16GKCVP-E nchasing this TOSHIBA Air Conditioner. Please read this owner’s manual carefully before using your Air Conr. Please read this installation manual carefully before installing the air conditioner. Veuillez lire attentivement ce manuel avant d’installer le climatiseur. Lesen Sie diese Einbauanleitung sorgfältig durch, bevor Sie das Klimagerät installieren.
  • Page 2 CONTENTS/SOMMAIRE/INHALT/INDICE/ÍNDICE/ΠΕΡΙΕΧΟΜΕΝΑ/ ÍNDICE/INNEHÅLL/СОДЕРЖАНИЕ ΕΛΛΗΝΙΚΑ ENGLISH 1 ΠΡΟΦΥΛΑΞΕΙΣ ΑΣΦΑΛΕΙΑΣ ........1 1 SAFETY PRECAUTIONS ..........1 2 ΕΙΚΟΝΕΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΕΣΩΤΕΡΙΚΗΣ ΚΑΙ 2 INSTALLATION DIAGRAM OF INDOOR AND ΕΞΩΤΕΡΙΚΗΣ ΜΟΝΑ∆ΑΣ ..........3 OUTDOOR UNITS ............3 3 ΠΡΟΑΙΡΕΤΙΚΑ ΑΝΤΑΛΛΑΚΤΙΚΑ, ΕΞΑΡΤΗΜΑΤΑ ΚΑΙ 3 OPTIONAL PARTS, ACCESORIES AND TOOLS ..4 ΕΡΓΑΛΕΙΑ...
  • Page 3: Safety Precautions

    1 SAFETY PRECAUTIONS For general public use Power supply cord of outdoor unit shall be 1.5 mm (H07RN-F or 245IEC66) polychloroprene sheathed flexible cord. CAUTION New Refrigerant Air Conditioner Installation • THIS AIR CONDITIONER ADOPTS THE NEW HFC REFRIGERANT (R410A) WHICH DOES NOT DESTROY OZONE LAYER.
  • Page 4 • Appliance shall be installed in accordance with national wiring regulations. • If you detect any damage, do not install the unit. Contact your Toshiba dealer immediately. CAUTION • Exposure of unit to water or other moisture before installation may result in an electrical short. Do not store in a wet basement or expose to rain or water.
  • Page 5: Installation Diagram Of Indoor And Outdoor Units

    2 INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS For the rear left and left 47 mm or more piping Hook a Installation Wall Hook plate 140 mm or more 74 mm or Insert the cushion between more Hook the indoor unit and wall, and tilt the indoor unit for better installation work.
  • Page 6: Optional Parts, Accesories And Tools

    Refrigerant piping Liquid side Gas side Indoor unit name (Outer diameter) (Outer diameter) 1 ea. RAS-B10GKVP-E, B13GKVP-E 6.35 mm 9.52 mm RAS-M10GKCVP-E, M13GKCVP-E RAS-B16GKVP-E, M16GKCVP-E 6.35 mm 12.7 mm Shield pipe (for extension drain hose) (polyethylene foam, 6 mm thick)
  • Page 7: Installation/Service Tools

    Installation/Service Tools Changes in the product and components In air conditioners using R410A, in order to prevent any other refrigerant from being accidentally charged, the service port diameter size of the outdoor unit control valve (3 way valve) has been changed. (1/2 UNF 20 threads per inch) •...
  • Page 8: Installation Of Indoor Unit

    4 INSTALLATION OF INDOOR UNIT Installation Location • A place which provides enough space around the indoor unit as shown in the diagram. ( see page 3.) • A place where there are no obstacles near the air inlet and outlet. •...
  • Page 9: Electrical Work

    Mounting the installation plate Anchor bolt holes a Installation plate Pipe hole Pipe hole g Mounting screw Indoor unit When the installation plate is directly mounted on the wall Securely fit the installation plate onto the wall by screws with the upper and lower catches, that hold the indoor unit, facing out. To mount the installation plate on a concrete wall use anchor bolts.
  • Page 10: Wiring Connection

    CAUTION • This appliance can be connected to a main circuit breaker in either of the following two ways. (1) Connection to fixed wiring: A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporate in the fixed wiring.
  • Page 11: Piping And Drain Hose Installation

    Piping and Drain Hose Installation Piping and drain hose forming • Since condensation results in machine trouble, make sure to insulate both the connecting pipes separately. (Use polyethylene foam as insulating material.) Rear right Rear left Bottom left Left Bottom right Right Die-cutting front panel slit Cut out the slit on the left or right side of the front panel for the left or right connection and the slit on the bottom left or right side of the...
  • Page 12 In case of right or left piping • After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool. Slit In case of bottom right or bottom left piping •...
  • Page 13: Indoor Unit Installation

    Indoor Unit Installation Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks. Swing the indoor unit to right and left to confirm that it is firmly hooked on the installation plate. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate.
  • Page 14: Installation Of Outdoor Unit

    5 INSTALLATION OF OUTDOOR UNIT Installation Location • A place which provides enough space around the outdoor unit as shown in the diagram. • A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration. •...
  • Page 15: Refrigerant Piping Connection

    Refrigerant Piping Connection Flaring Cut the pipe with a pipe cutter. Warp Roughness Obliquity Insert a flare nut into the pipe, and flare the pipe. • Projection margin in flaring: A (Unit: mm) Rigid (Clutch type) Outer diameter of copper pipe R410A tool used Conventional tool used 6.35...
  • Page 16 Evacuating After the piping has been connected to the indoor unit, perform the air purge. AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump. Do not use the refrigerant in the outdoor unit. For details, see the vacuum pump manual.
  • Page 17 Packed valve handling precautions • Open the valve stem all the way; but do not try to open it beyond the stopper. • Securely tighten the valve stem cap with torque in the following table: Gas side 50 to 62 N·m Hexagon wrench (φ12.7 mm) (5.0 to 6.2 kgf·m)
  • Page 18: Test Operation

    6 TEST OPERATION Valve cover Gas Leak Test • Check the flare nut connections for gas leaks with a Check places for gas leak detector and/or soapy water. indoor unit Electric parts cover Check places for outdoor unit Test Operation To test the system, press and hold RESET button for 10 sec.
  • Page 19 This product is compliant with Directive 2002/95/EC, and cannot be disposed as unsorted municipal waste. Ce produit est conforme à la Directive 2002/95/CE et il ne peut pas être jeté avec les ordures ménagères non triées. Dieses Produkt entspricht der Richtlinie 2002/95/EWG und darf nicht als normaler, unsortierter Hausabfall entsorgt werden.

Table of Contents