FfitTech Elliptical Silver Owner's Manual page 11

Table of Contents

Advertisement

will shift to Level item after pressing + or – Key. The Level item will return to Time
item if there is no key pressed during 3 seconds.
3. The screen will display heart pulse compulsorily if the console receives heart pulse
signal. The screen will not display calorie even if press Display Shift Key. If time is
progressed by counting down, the console will enter 【 【 【 【 Stop Mode】 】 】 】 when time counts
down to zero. Dot matrix will display the workout profile.
HRC Mode: : : : (L1: : : : 55%、 、 、 、 L2: : : : 70%、 、 、 、 L3: : : : 80%、 、 、 、 HR, , , , it can be performed only if the machine
is equipped with chest pulse.)
1. Select HRC Program by pressing HRC Key or+ / –key, Dot matrix will display『ONE
LINE』 profile and the corresponding indicator of HRC will turn on. The screen will display
『SELECT WORKOUT』and『PRESS ENTER』alternatively. Then【 【 【 【 Setting Mode】 】 】 】
starts.
2. Press ENTER, at this time, LED screen will display AGE , the values in the screen will flash.
Now users can press
25, step is 1) . According to the input value, the program will calculate the target pulse
value and press
3. LED screen will display 55% program mode and the calculated pulse value. Press
to select 55%, 70%, 80% or SET HR program mode. Press
4. LED screen will display TIME and flash. At this time, users can press
value. After the value is set, press
Time will be performed in positive number.
**The range of time: 1~99 minutes,preset value is 30 minutes. Step is 1.
5. 『SET HR 』is the mode in which the users can set target pulse value freely. Press
to modify Target HR setting. The setting range is 40~220 BPM. The preset value is
80BPM.
Press Quick Start Key and all values will start to accumulate which is the start of【 【 【 【 Operation
Mode】 】 】 】 .
After performing, LED screen will display 『WARM UP』for 2 minutes. After 2 minutes, the
screen will display 『BEGINNING HR』. Then start to carry out HRC Control.
When time is progressed by counting up, the profile will shift to next column every one minute.
When time is progressed by counting down, the profile will shift to next column every one
sixteenth of the set time. When one period is over, 『ONE LINE』 profile displayed in Dot
matrix will be cleared, then start a new period.
After carry out HRC, if any pulse is not detected after 60 seconds, the program will
automatically leave the screen and come back to start/ready status
INTERNATIONAL SALES Phone: +351 967960956 Fax: +351 232412003
Urbanização Valrio Lote 1, Vildemoinhos, 3510-431 Viseu, Portugal
ELLIPTICAL SILVER – OWNER'S MANUAL
to adjust the age (the range of age:10-99 years , preset value is
,
after confirm.
to confirm and press
11
www.ffittech.com
Email: geral@ffittech.com
,
after confirm.
,
to edit the
to start the program.
,

Advertisement

Table of Contents
loading