Table of Contents

Advertisement

NEEDLE DROP

TO CHECk:
When the needle swings in maximum zigzag width, the distance between both ends of the needle hole on the
needle plate and the needle drop positions should be equal.
If not, adjust as follows:
ADJUSTmENT PROCEDURE:
1. Remove the face cover (See page 4).
2. Set the pattern selector dial at maximum zigzag width.
3. Loosen the setscrew.
4. Turn the eccentric pin to adjust the needle drop.
5. Tighten the setscrew.
6. Attach the face cover.
NOTE: Check the hook timing after this adjustment.
mECHANICAL ADJUSTmENT
Setscrew
Both clearances should be equal
Setscrew
12