Electrical Adjustment

GROUP NO. ITEM
0 TERM_1
1 TEMR_2
140
Fan Output Level
0 Fan A Min
1 Fan A Max
2 Fan B Min
3 Fan B Max
4 Fan C Min
5 Fan C Max
6 Fan D1 Min
7 Fan D1 Max
8 Fan D2 Min
9 Fan D2 Max
10 Fan D3 Min
11 Fan D3 Max
12 Fan D4 Min
13 Fan D4 Max
141
Fan Option
0 Fan Output Level
1 Fan Cooling Mode
150
Factory Set (Reset)
0 Factory Set
1 Destination
170
Flow Sensor
0 Flow Sensor Calibration
1 Flow Sensor Offset Minimum
2 Flow Sensor Offset Maximum
3 Flow Sensor Calibration Error Log
4 Clog Check Enable
171
Flow Sensor
0 Ideal Flow Data
1 Flow Difference Data
2 Clog Detect Flow Difference Data
3 Warn Detect Flow Difference Data
4 Press Add Data
5 Filter Scroll Timer
175
Filter
0 Take up Bend
1 Take up Bend
2 Take up Times
3 Take up Time Reset
4 Scroll Counter Reset Time
176
Filter Display
0 Filter Icon display
177
Filter Timer Reset
0 Filter Counter Reset Times
180
DDC Setting
0 HDCP EDID Data Setting
1 DDC Data Automatic Renewal
190
Panel Life Test Pattern Display
0 Panel Life Test Pattern
200
Panel Option
0 Gamma Instance
280
Panel Option
0 G SIG Center
1 B SIG Center
FUNCTION
(1) 75 ohm terminate On / Off (0: Off, 1: On)
(2) Analog filter On/Off (0: Off, 1: On) on Input board side
Analog filter On/Off (0: Off, 1: On) on Main Board side
Fan A Driving Voltage Adj. at TP7611
Fan A Driving Voltage Adj. at TP7611
Fan B Driving Voltage Adj. at TP2661
Fan B Driving Voltage Adj. at TP2661
Fan C Driving Voltage Adj. at TP2671
Fan C Driving Voltage Adj. at TP2671
Fan D1 Driving Voltage Adj. at TPFN1
Fan D1 Driving Voltage Adj. at TPFN1
Fan D2 Driving Voltage Adj. at TPFN2
Fan D2 Driving Voltage Adj. at TPFN2
0 : Max / 1: Factory / 2 : Auto / 3 : Min / 99: Menu
0: Default, 1: FAN_C _MAX Fixed
Execute Factory setting when the value reaches 10.
0: English, 1: Japanese
Flow Sensor Offset Calibration
Execute auto-calibration when the value is set to 1
Flow Sensor Minimum Offset Value
Flow Sensor Maximum Offset Value
Auto-calibration Error Log
0: No Error
10: Unstabled at Minimum
11: Out of Range at Minimum
20: Unstabled at Maximum
21: Out of Range at Maximum
Cloggle Detection with Flow Sensor
0: Disable, 1: Enable
Read only
Read only
Read only
Read only
Read only
(Filter used time) Read only
Remove the filter bending
Remove the filter bending
Filter Scroll Remeining Times (Read only)
Reset the Filter Scroll Times
Reset when the value reaches 10
Reset Times of Sccroll Counter
0 : disable / 1 : Enable
User Menu Filter Counter Reset Times
0 : EDID Data for DVI / 1 : EDID Data for HDCP
0 : Enable / 1 : Disable
0 : White 73% Raster Step Pattern Display / 1 : Normal
Gamma IC direct
(Gamma IC directed here is displayed by the following
service mode)
(900 / 910 / 920 / 940 / 950 / 951 / 952 / 960 / 970 /
98000 : 74h / 1 : 76h
-71-
RANGE
INITIAL VALUE
0 / 1
0
0 / 1
0
0 ~ 255
150
0 ~ 255
48
0 ~ 255
208
0 ~ 255
14
0 ~ 255
192
0 ~ 255
28
0 ~ 255
192
0 ~ 255
32
0 ~ 255
192
0 ~ 255
32
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 3, 99
99
0 ~ 1
0
0 ~ 10
0
0 ~ 1
1
0 ~ 1
0
0 ~ 1023
0
0 ~ 1023
0
0 ~ 1
1
0 ~ 1
0
0 ~ 1
0
9
0 ~ 10
0
0 ~ 255
0
0 / 1
1
0 ~ 255
0
0 / 1
1
0 / 1
0
0 / 1
1
0 ~ 1
0
0 ~ 63
32
0 ~ 63
32
NOTE
* Fan Driving Voltage Adj.
* Fan Driving Voltage Adj.
* Fan Driving Voltage Adj.
* Fan Driving Voltage Adj.
* Fan Driving Voltage Adj.
* Fan Driving Voltage Adj.
* Fan Driving Voltage Adj.
* Fan Driving Voltage Adj.
* Fan Driving Voltage Adj.
* Fan Driving Voltage Adj.
* Filter Calibration Adj.