Rear Connector Panel D-Type Connectors - SoundCraft B800 User Manual

Table of Contents

Advertisement

23
1
3
6
19
B800 Functional Description
Remote Start/Stop
21
Two sets of relay contacts to start/stop external machines are available on the rear
connector panel d-type connector. These may be set to latching or pulsed operation
via internal jumpers. Note that these relays only operate when Line Input is selected
on the module. Under no circumstances should mains voltages be placed on
22
these contacts.
2
25
The ON switch works in conjunction with the fader's microswitch. The LED
4
in the ON switch will illuminate at half brightness if the fader is fully down when
the On button is pushed: this indicates that the remote start is armed. When the fader
5
is moved away from the fully-down position the start relay will be activated and the
LED in the ON switch will glow at full brightness. Alternatively, if the fader is
7
moved away from the fully-down position before the ON button is pushed, the relay
8
will operate as soon as the ON switch is pushed.
9
Meter
10
26
The 8-segment LED meter may be set to pre-fade (post Mute) or pre-eq by
an internal jumper.
11
12
27
The 3-input Peak LED monitors pre-EQ, post-EQ and post-fade. If any of
13
these points rises to 6dB below clipping the LED will illuminate.
14
15
16
17
18
24
27
26
20
25
4.5