7. Install the coil support bracket on the opposite side of
the air handler (figure 7, detail B).
Drains
RIGHT-HAND DRAINS
Figure 6. Right-Hand Discharge Configuration
DETAIL A
Figure 8. Right-Hand Drain Plug Location
505059M 0511
AIR FLOW
KNOCKOUT
REMOVE DRAIN PAN FROM HERE
THEN...
REMOVE 2 SCREWS, BLOW OFF PREVENTION
BRACKET(S), AND DRIP SHIELD FROM HERE
ROTATE SHIELD AND BRACKET AND REINSTALL
NOTE − EXPANSION VALVE SHOWN ON
COIL IS NOT ON CB26UH−R (RFC)
EQUIPPED UNITS.
REMOVE COIL SUPPORT BRACKET FROM HERE
THEN...
BRACKET SHOWN AS SHIPPED
BRACKET SHOWN FOR RIGHT HAND DISCHARGE
Figure 7. Field Modification for Right−Hand Discharge
PLUGGED
END
OPEN END FOR CONDENSATION
DRAIN
Table 2. Blow Off Prevention Bracket
Model
−018
−024
−030
−036
−037
−042
−048*
−060
* −048 model supported in TXV units only.
REINSTALL PAN HERE
THEN...
REINSTALL BRACKET HERE
REFRIGERANT METERING DEVICE
NOTE
See the outdoor unit installation instructions and
the Lennox Engineering Handbook for approved fixed
orifice match−ups and application information.
CB26UH−R units are equipped with a factory−installed
refrigerant flow control (RFC) device (see table 1 on
Page 3).
IMPORTANT
If a unit equipped with an RFC device is used in an ap-
plication which requires conversion to an expansion
valve, the fixed orifice must be removed before the ex-
pansion valve is installed.
Page 6
Front
Rear
None
None
None
None
Yes
Yes
Yes
Yes
None
None
None
None
Yes
None
Yes
None
DETAIL B