DATA
6
MSH09TW -
MSH09TW
MSH12TN -
MSH12TN
MSH15TN -
MSH15TN
MSH17TN -
MSH17TN

6-1. PERFORMANCE DATA

1) COOLING CAPACITY
(115V)
Indoor air
Model
IWB
( ˚F )
71
MSH09TW
67
MSH09TW -
U1
63
(208V)
Indoor air
Model
IWB
( ˚F )
71
MSH12TN
67
MSH12TN -
U1
63
71
MSH15TN
67
MSH15TN -
U1
63
71
MSH17TN
67
MSH17TN -
U1
63
(230V)
Indoor air
Model
IWB
( ˚F )
71
MSH12TN
67
MSH12TN -
U1
63
71
MSH15TN
67
MSH15TN -
U1
63
71
MSH17TN
67
MSH17TN -
U1
63
MUH09TW -
MUH09TW
U1
MUH12TN -
MUH12TN
U1
MUH15TN -
MUH15TN
U1
MUH17TN -
MUH17TN
U1
75
TC
SHC
TPC
TC
SHC
10.8
6.1
0.79
10.1
10.2
7.1
0.75
9.5
9.6
8.0
0.71
8.9
75
TC
SHC
TPC
TC
SHC
15.4
8.9
1.14
14.4
14.6
10.4
1.08
13.6
13.7
11.6
1.02
12.7
10.7
17.5
9.1
1.20
16.4
16.6
10.8
1.13
15.4
10.0
15.6
12.2
1.08
14.4
11.3
19.6
9.9
1.39
18.3
18.6
11.9
1.31
17.3
11.1
17.4
13.5
1.25
16.2
12.5
75
TC
SHC
TPC
TC
SHC
15.8
9.1
1.17
14.8
15.0
10.6
1.10
13.9
14.1
11.9
1.05
13.0
17.9
9.2
1.23
16.7
16.9
11.0
1.16
15.8
15.9
12.5
1.10
14.7
19.8
10.1
1.41
18.5
18.8
12.0
1.33
17.5
17.7
13.7
1.26
16.4
U1
MUH12TN -
U1
MUH15TN -
U1
U1
Outdoor intake air DB temperature ( ˚F )
85
95
TPC
TC
SHC
TPC
5.7
0.87
9.5
5.4
0.93
6.7
0.82
8.8
6.2
0.89
7.4
0.79
8.3
6.9
0.85
Outdoor intake air DB temperature ( ˚F )
85
95
TPC
TC
SHC
TPC
8.3
1.25
13.5
7.8
1.34
9.7
1.18
12.6
8.9
1.28
1.13
11.8
10.0
1.22
8.5
1.32
15.4
7.9
1.42
1.25
14.3
9.3
1.35
1.19
13.4
10.5
1.29
9.3
1.52
17.2
8.7
1.64
1.44
16.0
10.2
1.56
1.38
15.0
11.6
1.49
Outdoor intake air DB temperature ( ˚F )
85
95
TPC
TC
SHC
TPC
8.5
1.28
13.9
8.0
1.38
9.9
1.21
12.9
9.2
1.31
11.0
1.16
12.1
10.2
1.25
8.6
1.35
15.7
8.1
1.45
10.2
1.28
14.6
9.5
1.38
11.6
1.22
13.7
10.8
1.32
9.4
1.54
17.4
8.8
1.66
11.2
1.46
16.2
10.4
1.58
12.7
1.40
15.2
11.8
1.51
NOTE 1. IWB : Intake air wet-bulb temperature
TC : Total Capacity (x10
TPC : Total Power Consumption (kW)
2. SHC is based on 80˚F of indoor intake air DB temperature.
17
U2
U2
105
TC
SHC
TPC
TC
8.8
5.0
0.98
8.1
8.2
5.7
0.94
7.5
7.5
6.3
0.91
6.9
105
TC
SHC
TPC
TC
12.6
7.3
1.41
11.6
11.7
8.3
1.36
10.8
10.8
9.1
1.31
9.8
14.3
7.4
1.49
13.2
13.3
8.6
1.43
12.2
12.2
9.6
1.38
11.2
16.0
8.1
1.72
14.7
14.9
9.5
1.65
13.7
13.7
10.6
1.59
12.5
105
TC
SHC
TPC
TC
12.9
7.4
1.45
11.9
12.0
8.5
1.39
11.0
11.0
9.3
1.34
10.1
14.6
7.5
1.52
13.4
13.6
8.8
1.46
12.5
12.5
9.8
1.41
11.4
16.2
8.2
1.75
14.9
15.1
9.6
1.67
13.9
13.9
10.7
1.61
12.6
3
Btu/h), SHC : Sensible Heat Capacity (x10
115
SHC
TPC
4.6
1.02
5.3
0.99
5.7
0.94
115
SHC
TPC
6.7
1.47
7.6
1.42
8.3
1.36
6.8
1.55
7.9
1.50
8.7
1.43
7.5
1.79
8.8
1.73
9.7
1.65
115
SHC
TPC
6.8
1.51
7.8
1.45
8.5
1.39
6.9
1.59
8.1
1.53
8.9
1.46
7.6
1.82
8.9
1.75
9.8
1.67