Installation Sequence

The heater is sent with all parts necessary for installation with the exception of chain.
It is recommended that the heater be hung as high as possible and along an uncluttered wall to give the
reflector a widest possible "view" of the space to be heated. Avoid installation directly over vehicle
parking, over cabinets, or where an open door will interfere. Adhere to minimum clearances on the rating
plate.
Leave adequate space around the burner box for future servicing.
Choose a location that permits easy installation of exterior venting. A horizontal vent length up to 10' feet
is allowed. For vertical venting adhere to local venting tables and methods.
Note:
Close all open ended "S" hooks, chain links,
and turnbuckles or any open connection.
Figure 3: General Overview of Components Utilized in the Installation
As required, fasten hanging angles to ceiling such that heater-hanging points can be accommodated.
Each hanging point must be able to hold at least 150 lbs.
Allow for movement of heater during expansion and contraction during operating cycle.
Heater must fire horizontally. To tilt reflector at 45°, lengthen two of the hanging points to an appropriate
length using chain. (Each chain length will be approximately 12" inches longer than the high side of the
heater). SRP recommends and make available "quick links" for connecting chain. If any open
ended "S" hooks and turnbuckles are used, the open ends must be closed to avoid unhooking chain
with inadvertent contact.
Series GR
Fasten Support Angle to Ceiling to
Accommodate Heater Hanging Points
96.00"