Installation Detail
8.39" or ("B/3") Max.
24.00" Min. or ("B")
Figure 5: Mounting Distances for Outdoor Installations under Eaves.
8.00" Max. or ("B/3")
8.00" Max. or ("B/3")
28.00" Min. or ("B")
28.00" Min. or ("B")
Figure 6: Mounting Distances for Tilted (45°) Outdoor Installations under Eaves.
In the case where the heater is installed at a 45° angle, the minimum dimension inside the overhang is 28"
from both the back and side of the burner box and 8" maximum on the top. If the side or back dimensions
are increased then the top clearance may be increased using the same rules as for a horizontal installation.
NOTE: These dimensions are only for satisfying outdoor heater positioning. Clearance
to combustible must also be satisfied.
Series GR
Page 11
February 10, 2014