Sharp LC-15B2U Service Manual page 14

Lcd color television
Hide thumbs Also See for LC-15B2U:
Table of Contents

Advertisement

LC-15B2U
3. Cancel of special mode
Turn off the main unit power.
4. Adjustments
Adjustment
1
B+ Adjustment
(R3760)
2
Model and Inch Size
setup
(If E
2
PROM is replaced)
(IC2004)
3
Counter-bias adjustment
4
Checking and modifying
the settings
(after replacing the
2
E
PROM)
Adjusting conditions
1. Connect the DC voltmeter to
pin 38 of SC3403.
1. Go to the adjustment mode.
1. Receive a B/W channel.
2. Go to the adjustment mode.
3. Select the "COM BIAS" with
[MENU] key.
1. Go to the adjustment mode and
check the following settings.
» PRE SCALE FM/AM-M
» PRE SCALE SCART
» TV GEQ BAND 1
» TV GEQ BAND 2
» TV GEQ BAND 3
» TV GEQ BAND 4
» TV GEQ BAND 5
» EXT GEQ BAND 1
» EXT GEQ BAND 2
» EXT GEQ BAND 3
» EXT GEQ BAND 4
» EXT GEQ BAND 5
» VSYNC DELAY
14
Adjusting method
1. Adjust the "B+ Adj" value to
5.0 ±0.02V with R3760.
1. Select "MODEL" with [MENU] key
and adjust to "B2U" with [VOL+] or
[VOL-] key.
* The color of "MODEL" must be yellow.
2. Select "INCH SIZE" and adjust to
"15" with [VOL+] or [VOL-] key.
* The color of "INCH SIZE" must be
yellow.
1. Adjust "COM BIAS" to the darkest
screen with [VOL+] and [VOL-] key.
* The color of "COM BIAS" must be
yellow.
1. See if all the settings are as
specified. If not, select an item in
17
question with [VOL+] or [VOL-] key
and adjust the setting as shown at
15
left.
* An item selected will be highlighted
+1.0
in yellow.
+1.0
-1.0
-2.0
-2.0
+1.0
+1.0
-1.0
-2.0
-2.0
29