Advertisement

INSTALLING THE PVC INTAKE VENT KIT ON THE MASTERTEMP
When installing this kit, basic safety precautions should always be followed. Read and follow all instructions.
Required installation tools:
Powered socket/nut driver
1/4" nut driver bit
5/16" socket and nut driver
3/8" nut driver
To install the PVC Intake Kit on the MaterTemp
1.
Remove right side panel from the heater (Fig. 1).
FIG. 1
2.
Loose air orifice top and bottom screws on the blower
(Fig. 2 and Fig. 3).
FIG. 2
FIG. 3
4.
Remove air orifice from the blower (Fig. 4).
FIG. 4
®
Heater:
MasterTemp
®
125 Heater
3
5.
Attach and secure the adapter with pvc pipe to the air
orifice with three self-tapping screws provided (Fig. 5).
FIG. 5
6.
Install and secure air orifice back on the blower with
two top and bottom screws (Fig. 6).
FIG. 6
7.
Install and secure side panel with the PVC pipe
protruding through the side panel (Fig. 7).
FIG. 7
8.
Install and secure half of 3" PVC union on the pipe
with plastic pipe cement (Fig. 8).
FIG. 8
9.
Place and secure screened vent cap on the top of the
last vent pipe section with two screws provided.
®
HEATER
®