DEFROSTING AND MEASURES FOR PROLONGED PERIODS OF DISUSE

A build up of too much ice on the evaporator hinders cooling of the unit and thus
reduces effectiveness. When there is an approximately 5-mm-thick layer of ice
build-up it is recommended to defrost the cooling unit. Thus, the cooling unit will
be turned off and any goods to be cooled removed. Never use heated appliances,
heaters, etc. to speed up the defrosting process! if necessary, a cloth dipped in warm
water can be placed on the unit to help the defrosting process. After defrosting,
clean up the defrosted water with a clean cloth and clean the cooler containers.
should the unit be out of operation for a prolonged period, turn off unit and remove
contents. After defrosting, the cooler should be cleaned carefully and dried.
To avoid the build-up of any unpleasant smells in the cooler, it is recommended to leave the
lid slightly open.

MEASURES AFTER PROLONGED PERIODS OF DISUSE

should the cooling unit not function correctly when switched on after being out of operation
for a prolonged period, ShUT Off ThE POWER SUPPLy AND DISCONNECT then turn the
appliance upside down.
After a few minutes return the appliance to its upright position and switch on again. should
the unit still not function correctly, repeat the process several times.

MAINTENANCE

changing the gas filter: the cellulose gas filter is situated at the back in the gas connection
piece. When it becomes necessary to replace the gas filter, remove the filter from the duct
and replace it with a new one. Any other maintenance and repair works, especially those
relating to the cooling aggregate and the gas-burner system, may only be undertaken by
authorized customer service points.

AfTer-SAleS ServICe

should a problem arise with the unit, please check the following before contacting customer
service:
is the unit suitably placed and is it well ventilated?
is the unit placed on a flat surface?
does the socket supply current?
is the connecting cable damaged in any way?
is there a loose connection?
has the plug been properly plugged into the socket?
has the electrothermostat been correctly adjusted?
in the case of gas operation, has the safety pilot knob (regulator) been pressed
down long enough?
has the regulating knob been turned to the correct position?
is the gas cylinder or pressure regulating valve open?
does the liquid gas cylinder still contain gas? if no liquid movement is evident on
shaking the cylinder, then the gas cylinder is empty.
are several operating methods being used simultaneously?
have warm foodstuffs been stored in the cooler?
was a too large a quantity of food or drink stored at any one time? food and drink
should be so stored as to allow free air circulation. Do not use paper or plastic
plates. Always keep containers for liquids sealed.