GENERAL INSTALLATION INSTRUCTIONS
Insulation of Pipes
All hot water pipes must be insulated with UV stabilised insulation.
Temperature Protection
Water heaters can produce very hot water. To reduce the risk of scald injury, it is mandatory under
the requirements of Australian Standard AS/NZS 3500.4 that a suitably approved temperature control
device be fitted to the hot water supply to outlets used primarily for personal hygiene. This valve
should be checked at regular intervals to ensure its operation and settings remain correct.
Inlet Connections
Isolating Valve
(Spindle Vertical)
Cold Water
Inlet
A combined isolating valve/non-return valve/line strainer may be used. Expansion
valve only required where local regulations demand or when the water saturation
NOTE
index is greater than 0.4.
Rinnai Australia
Drain
Line
Non-return
Strainer
Valve
Figure 2 - Inlet Connections
7
Expansion
Valve
Union
Connection
Operation & Installation Manual