Patton electronics 1195/4E1 Getting Started Manual

Optical
Table of Contents

Advertisement

Quick Links

For Quick
Start Installation
Getting Started Guide
Sales Office:
+1 (301) 975-1000
Technical Support:
+1 (301) 975-1007
E-mail:
support@patton.com
WWW:
www.patton.com
Part Number: 07M1195-GS, Rev. A
Revised: February 12, 2009

Advertisement

Table of Contents
loading

Summary of Contents for Patton electronics 1195/4E1

  • Page 1 For Quick Start Installation Getting Started Guide Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: support@patton.com WWW: www.patton.com Part Number: 07M1195-GS, Rev. A Revised: February 12, 2009...
  • Page 2 Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or...
  • Page 3 Summary Table of Contents General information............................13 Applications overview ............................21 Model 1195/4E1 installation..........................23 Connecting the RS-232 port ..........................29 configuration...............................34 GUI configuration ..............................47 Contacting Patton for assistance........................66 Specifications ..............................69 Connector pinouts .............................74...
  • Page 4: Table Of Contents

    ............................12 General information............................13 Model 1195/4E1 Overview...........................14 Features and Benefits ............................14 Front View................................15 Rear View................................20 Applications overview ............................21 Typical Model 1195/4E1 Application.........................22 Model 1195/4E1 installation..........................23 Connecting power ..............................24 AC Power ...............................24 DC Power ...............................24 Grounding ..............................25 Connecting the optical interface...........................26 Connecting the DB-37 connector.........................27...
  • Page 5 Model 1195 Getting Started Guide Table of Contents Change the Gateway information of the device ....................38 Change the MAC address of the device ......................39 Show system information ..........................39 Enable / Disable the loopback of E1 Port ......................40 Check whether the E1 Port is looped back ....................40 Check the alarms of E1 Tributary ........................41...
  • Page 6 Model 1195 Getting Started Guide View log ................................55 Managing Trap Details............................55 Configuring System Settings..........................55 Configuring IP Settings............................56 Configuring Trap Settings............................57 Configuring Default Settings ..........................58 SNMP Community...............................59 Viewing Settings ..............................60 Back Up................................61 Restore..................................61 Synchronize................................62 Report ...................................62 List of systems ...............................62 List of traps ..............................63 Read Me...
  • Page 7 Model 1195 Getting Started Guide Table of Contents Physical ................................73 Connector pinouts .............................74 DB-37 connector pinout (Model 1195/4E1)......................75 DB-37 connector pinout details for E1 connections ..................75...
  • Page 8 Typical application for Model 1195/4E1 ........
  • Page 9: About This Guide

    About this guide This guide describes the Model 1195/4E1 hardware, installation and basic configuration. Audience This guide is intended for the following users: • Operators • Installers • Maintenance technicians Structure This guide contains the following chapters and appendices: •...
  • Page 10 Precautions Notes, cautions, and warnings, which have the following meanings, are used throughout this guide to help you become aware of potential problems. Warnings are intended to prevent safety hazards that could result in per- sonal injury. Cautions are intended to prevent situations that could result in property damage or impaired functioning.
  • Page 11: Safety When Working With Electricity

    Model 1195 Getting Started Guide Safety when working with electricity • This device contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service personnel. WARNING • Mains Voltage: Line voltages are present when the power cord is con- nected.
  • Page 12: General Conventions

    Model 1195 Getting Started Guide Typographical conventions used in this document This section describes the typographical conventions and terms used in this guide. General conventions The procedures described in this manual use the following text conventions: Table 1. General conventions Convention Meaning Indicates a cross-reference hyperlink that points to a figure, graphic, table, or sec-...
  • Page 13: General Information

    Chapter 1 General information Chapter contents Model 1195..........................14 Features and Benefits ........................14 Front View ...........................15 Rear View.............................20...
  • Page 14: Model 1195/4E1 Overview

    Model 1195 Getting Started Guide 1 • General information Model 1195 FiberLink E1/Ethernet Mux is a point to point high performance optical line transmission equipment, combines 8, ITU-T G.703 compliant standard electrical E1s plus 100BaseT Ethernet signal into an optical data stream for transport over fiber optic pairs. Several transmitter options for different cable types and wave-lengths are available.
  • Page 15: Front View

    Model 1195 Getting Started Guide 1 • General information Front View Front View...
  • Page 16 Model 1195 Getting Started Guide 1 • General information Name Color Function Green ON – Unit is powered OFF – Unit is off ON – Local alarm detected Blinking – Remote alarm detected OFF – No alarm currently detected The local alarms take priority over remote alarms. Yellow ON –...
  • Page 17 Model 1195 Getting Started Guide 1 • General information Name Color Function E1-LOS ON – E1 signal loss happened at the corresponding tributary OFF – No loss Front View...
  • Page 18 Model 1195 Getting Started Guide 1 • General information Name Function CV-CLR ON – Clear CV alarm MUTE ON – Alarm sound is muted. Speaker will sound if any alarms have occurred. OFF – Speaker will not sound if there are alarms. Note that the ringing of the order wire cannot be muted.
  • Page 19: Interfaces

    Model 1195 Getting Started Guide 1 • General information S.No. Name Description MANG Ethernet Management Interface (RJ-45) Cable: CAT-5 crossover or straight through Note: In default Telnet User Name : superuser (case sensitive) Password: superuser (case sensitive) Ethernet Interface (RJ-45) Cable: CAT-5 crossover or straight through PHONE Phone Interface (RJ-11)
  • Page 20: Rear View

    Model 1195 Getting Started Guide 1 • General information Rear View Rear View...
  • Page 21: Applications Overview

    Chapter 2 Applications overview Chapter contents Typical Model 1195 Application........................22...
  • Page 22: Typical Model 1195/4E1 Application

    Model 1195 Getting Started Guide 2 • Applications overview Typical Model 1195 Application Figure 8 shows the typical application for the 1195 model. Figure 8. Typical application for Model 1195 Typical Model 1195 Application...
  • Page 23 Chapter 3 Chapter contents Connecting power ..............................24 AC Power ...............................24 DC Power ...............................24 Grounding ..............................25 Connecting the optical interface ..........................26 Connecting the DB-37 connector..........................27 Connecting E1 links ..............................28 Definition for E1 Interfaces ..........................28 Connecting Ethernet Links............................28 Verifying the connection ..........................28 Definition for Ethernet Interfaces ........................28...
  • Page 24: Model 1195/4E1 Installation

    Model 1195 Getting Started Guide 3 • Model 1195installation Connecting power AC Mains version: Please use the AC main cable (provided) to connect the system to your AC mains power outlet. DC Mains version: Please connect the DC mains cable (provided) to the system. The polarity should not be reversed while connecting.
  • Page 25: Grounding

    Model 1195 Getting Started Guide 3 • Model 1195 installation Grounding When the equipment is used with the AC~220V power supply, the 3-core socket must be grounded for protec- tion.The other equipment, e.g. optical terminal, connected with this equipment must also be grounded To connect the Earth: Connecting power...
  • Page 26: Connecting The Optical Interface

    Model 1195 Getting Started Guide 3 • Model 1195 installation Connecting the optical interface For Testing: Always Install Optical Attenuators. For distances of less than 10 km, optical attentuators must be intalled on the Optical Links. Otherwise, the optics will be permanently damaged. WARNING Connecting the optical interface...
  • Page 27: Connecting The Db-37 Connector

    Model 1195 Getting Started Guide 3 • Model 1195 installation Connecting the DB-37 connector Note Appendix B on page 74 for DB-37 connector pinouts. Connecting the DB-37 connector...
  • Page 28: Connecting E1 Links

    Model 1195 Getting Started Guide 3 • Model 1195 installation Connecting E1 links Connect E1 line after ensuring that transmission device have been grounded. A Bit Error Rate (BER) test may be conducted on E1 Link using a BERT tester to ensure that the E1 errors are within the permitted limits / threshold.
  • Page 29: Connecting The Rs-232 Port

    Chapter 4 Connecting the RS-232 port Chapter contents Connecting the RS-232 port ..........................30 RS-232 port cable details ..........................31 RS-232 pin definition .............................31 Configuring HyperTerminal ..........................32...
  • Page 30: Connecting The Rs-232 Port

    Model 1195 Getting Started Guide 4 • Connecting the RS-232 port Connecting the RS-232 port Connecting the RS-232 port...
  • Page 31: Rs-232 Port Cable Details

    Model 1195 Getting Started Guide 4 • Connecting the RS-232 port RS-232 port cable details End 1 DB-9 (Female Connector) End 2 DB-9 (Female Connector) Type of cable Twisted pair cable - solid conductor Number of pairs Diameter 24 AWG Length 3 meters Connections...
  • Page 32: Configuring Hyperterminal

    Model 1195 Getting Started Guide 4 • Connecting the RS-232 port Configuring HyperTerminal 1. Click on the Start button from the task bar on your PC. 2. Select Programs > Accesories > Communications > HyperTerminal. The following screen will be dis- played: 3.
  • Page 33 Model 1195 Getting Started Guide 4 • Connecting the RS-232 port 5. Change the Bits per second option to 19200 and change the flow control option to None. The COM Properties settings should be: Bits per second 19200 Data bits Parity None Stop bits...
  • Page 34: Cli Configuration

    Chapter 5 CLI configuration Chapter contents General Commands ..............................35 Specific Commands..............................37 Check current MAC address of the device ....................37 Check the current IP address of the device ....................37 Check gateway address of the device ......................37 View the get / getnext community of SNMP ....................37 Configure the get / getnext community of SNMP ..................37...
  • Page 35: General Commands

    Model 1195 Getting Started Guide 5 • CLI configuration General Commands After entering into the application program for CLI commands, press the “?” key in the command line to get the list of the commands. Command Description ?/help To get a list of commands for the system showmac View MAC address showip...
  • Page 36 Model 1195 Getting Started Guide 5 • CLI configuration For detailed command format, please key "? cmdname" or "help cmdname". See the following examples: Command Example Notes 1195#? [cmdname] To get further information about any 1195#? sete1loop {enter} command, type the command fol- <FORMAT>: sete1loop[E1ID] lowed by “?”.
  • Page 37: Specific Commands

    Model 1195 Getting Started Guide 5 • CLI configuration Specific Commands Check current MAC address of the device Command Response Notes 1195#showmac Shows the MAC address of the local System MAC Address: {enter} device 00.13.20.E8.86.76 Check the current IP address of the device Command Response Notes...
  • Page 38: View The Set Community Of Snmp

    Model 1195 Getting Started Guide 5 • CLI configuration View the set community of SNMP Command Response Notes 1195#showsnmpset Shows the SET community of SNMP System SNMP set community: {enter} public of the local device Configure set community of SNMP Command Response Notes...
  • Page 39: Change The Mac Address Of The Device

    Model 1195 Getting Started Guide 5 • CLI configuration Change the MAC address of the device Command Response Notes 1195#setmac [macaddr] Change the MAC of the local device, MAC Address: [macaddr] {enter} where [macaddr]=any valid MAC address Note: A new MAC address will be activated after a system reset.
  • Page 40: Enable / Disable The Loopback Of E1 Port

    Model 1195 Getting Started Guide 5 • CLI configuration Enable / Disable the loopback of E1 Port Command Response Notes 1195#sete1loop [E1ID] [local_loop] Enable/Disable the loopback of E1 E1ID: <0-8>,0: All; 1-8 [remote_loop] :E1ID port. Use this command to put the E1 {enter} line into loopback mode or non-loop- Local_Loop: <0/1>, loop...
  • Page 41: Check The Alarms Of E1 Tributary

    Model 1195 Getting Started Guide 5 • CLI configuration Check the alarms of E1 Tributary Command Response Notes 1195#e1alarm Shows the alarms of E1 tributary. See Shows the alarms of E1 tributary. {enter} example below. Configure laser port receive mode Command Response Notes...
  • Page 42: View The Current Status Of Laser Port

    Model 1195 Getting Started Guide 5 • CLI configuration View the current status of laser port Command Response Notes 1195#showlaser View the status of laser interface. View the status of laser interface. {enter} Include alarm status, the config of Include alarm status, the config of receive mode, the current work inter- receive mode, the current work inter- face.
  • Page 43: Set / Configure The Ethernet Port Performance Parameters

    Model 1195 Getting Started Guide 5 • CLI configuration Set / configure the Ethernet Port performance parameters Command Response Notes 1195#setport [port] [AN] [rate] Port=A, AN=B, Rate=C, Duplex=D, Configure the Ethernet port perfor- [duplex] [flow] Flow=E mance parameters, where: {enter} A=1 (Ethernet Port No.) B=0:AN not done, 1:AN done C=0:10Mbit/s;...
  • Page 44: View The Performance Of Ethernet Port

    Model 1195 Getting Started Guide 5 • CLI configuration View the performance of ethernet port Command Response Notes 1195#ethperform View the performance of Ethernet. View the performance of Ethernet. {enter} View the status of ethernet port Command Response Notes 1195#ethstatus View the status of Ethernet.
  • Page 45: Add A Telnet User

    Model 1195 Getting Started Guide 5 • CLI configuration Add a telnet user Command Response Notes 1195#adduser [Username] Adds a telnet user, where user- TELNET Manage Username: [Password] Username name=<a string (1-31 Bytes)>, user TELNET Manage Password: {enter} login name. Password=<a string (1- Password 31) Bytes)>, user login password.
  • Page 46: Clear The Record Of E1'S Cv Alarm

    View the status of alarm tone mask. View the status of alarm tone mask. {enter} View the contact details Command Response Notes 1195#showcontact Patton Electronics Company View the contact details of the {enter} 7622, Rickenbacker Drive company. Gaithersburg, MD 20879 Email: support@patton.com + (301) 975-1000...
  • Page 47 Chapter 6 GUI configuration Chapter contents Overview ................................48 Installing the GUI ..............................48 Adding/Removing a System...........................49 Adding a system ..............................49 Removing a system ............................50 Editing a system ..............................50 Communicating With a System..........................51 Adding/Removing Users............................52 Adding a user ..............................52 Removing a user ..............................52 Editing a user entry ............................52...
  • Page 48: Gui Configuration

    Model 1195 Getting Started Guide 6 • GUI configuration Overview This chapter describes how to use the Graphical User Interface (GUI) to access and configure the Model 1195. Installing the GUI 1. Insert the CD that came with the 1195 into the CD-ROM drive. The CD will automatically start and display the main window.
  • Page 49: Accessing The 1195

    Model 1195 Getting Started Guide 6 • GUI configuration Accessing the 1195 The Model 1195 GUI helps in configuring the 1195 system through a serial port connection between the equipment and a PC or to establish a remote login to the equipment. It also allows the user to configure the system as desired and also provides the information about the status of the system.
  • Page 50: Removing A System

    Model 1195 Getting Started Guide 6 • GUI configuration Figure 11. Add/Remove System 2. Click New . Enter information for all of the fields. 3. Click Add. The system will be added. The GUI supports up to 2,000 systems. Note When you are entering the information for the new system, assign the correct IP address of that system.
  • Page 51: Communicating With A System

    Model 1195 Getting Started Guide 6 • GUI configuration Communicating With a System To communicate with the system, you have to make a connection with the system through a TCP or COM port. To select a COM port: 1. Click on the Option menu at the top of the screen and select TCP/COM (Single System). Figure 12.
  • Page 52: Adding/Removing Users

    Model 1195 Getting Started Guide 6 • GUI configuration 4. To change the IP address, connect to the system with the COM port using an RS-232 cable. 5. Click on Settings > IP Settings. Click OK. A login window will display. 6.
  • Page 53: Status Monitoring

    Model 1195 Getting Started Guide 6 • GUI configuration Status Monitoring To view the status and current alarms of the 1195 click on Tributary Interface at the top of the screen and select Status Monitoring. Figure 16. Status Monitoring If a status is Red, there is an alarm. If the status is Green, there is no alarm.
  • Page 54: System Monitoring

    Model 1195 Getting Started Guide 6 • GUI configuration System Monitoring To monitor the alarms of all the systems present in the network, click on Communication at the top of the screen and select MultiSystem Monitor (NMS). A list of the systems will display. Figure 17.
  • Page 55: View Log

    Model 1195 Getting Started Guide 6 • GUI configuration View log Click the View Log button at the bottom of the screen to view details of all of the traps received to date. Refresh the systems list to view the most current information. Note Managing Trap Details To view the details of traps for the last ten days, click on Communication at the top of the screen and select...
  • Page 56: Configuring Ip Settings

    Model 1195 Getting Started Guide 6 • GUI configuration To configure settings for E1 and Mask, click on Settings at the top of the screen and select E1 Set- tings. A window will display where you can make the desired changes. Figure 19.
  • Page 57: Configuring Trap Settings

    Model 1195 Getting Started Guide 6 • GUI configuration Figure 20. IP settings Note Changing MAC addresses will reset the system. Configuring Trap Settings To configure the settings for receiving traps, click on SNMP at the top of the screen and select Trap Settings. A window will display where you can create a list of monitoring systems to which traps will be sent by the selected device.
  • Page 58: Configuring Default Settings

    Model 1195 Getting Started Guide 6 • GUI configuration Configuring Default Settings To restore the default settings, click on Set Default at the top of the screen. A window will display. Click Yes to begin the process. Figure 22. Default settings The default settings are: Laser Mode E1 Local Loop...
  • Page 59: Snmp Community

    Model 1195 Getting Started Guide 6 • GUI configuration SNMP Community To set and view the SNMP Set and SNMP Get Community options, click on SNMP at the top of the screen and select SNMP Community. A window will display. Figure 23.
  • Page 60: Viewing Settings

    Model 1195 Getting Started Guide 6 • GUI configuration Viewing Settings To view general system settings, click on Show Settings at the top of the screen . A window will display that shows current system values. Click on any of the properties displayed in the list and the details will be displayed in the Result window.
  • Page 61: Back Up

    Model 1195 Getting Started Guide 6 • GUI configuration Back Up To create a backup of all of the settings, click on File at the top of the screen and select Back Up. A screen will display. Click Open and select the path where you want to save the backup file. Click Save. Figure 25.
  • Page 62: Synchronize

    Model 1195 Getting Started Guide 6 • GUI configuration Synchronize To synchronize the system, click on File at the top of the screen and select Synchronize. A screen will display. Click Yes to start the process. The purpose of synchronization is to update the database with the current set- tings in the system.
  • Page 63: List Of Traps

    Model 1195 Getting Started Guide 6 • GUI configuration List of traps To view the report of the list of traps, click on File at the top of the screen and select Report > List of Traps. A screen will display. To view the traps of a specific system, click on Traps of Selected System. To view traps of all the systems, click on Traps of All Systems.
  • Page 64: Read Me

    Model 1195 Getting Started Guide 6 • GUI configuration Read Me To learn about system requirements for running the GUI, click on Help at the top of the screen and select Read Me. The instructions will display in a window. Figure 30.
  • Page 65: System Information

    Model 1195 Getting Started Guide 6 • GUI configuration System Information To learn about firmware and GUI release versions, click on Help at the top of the screen and select About. A window will display with the system information. Figure 31. View system information Exiting the System To disconnect from the system, click on File at the top of the screen and select Exit.
  • Page 66: Contacting Patton For Assistance

    Chapter 7 Contacting Patton for assistance Chapter contents Introduction ................................67 Contact information..............................67 Patton support headquarters in the USA ......................67 Alternate Patton support for Europe, Middle East, and Africa (EMEA) ............67 Warranty Service and Returned Merchandise Authorizations (RMAs)..............67 Warranty coverage ............................67 Out-of-warranty service ..........................68 Returns for credit...
  • Page 67: Introduction

    (RMA). Contact information Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.
  • Page 68: Out-Of-Warranty Service

    Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows: Patton Electronics Company RMA#: xxxx 7622 Rickenbacker Dr.
  • Page 69: Specifications

    Appendix A Specifications Chapter contents E1 Interface ................................70 Optical ..................................70 Optical Interface Specifications: 1310nm Single Mode..................71 Transmitter Optical Characteristics .........................71 Receiver Optical Characteristics ........................71 Optical Interface Specifications: 1550nm Single Mode..................71 Transmitter Optical Characteristics .........................71 Receiver Optical Characteristics ........................72 Safety..................................72 Ethernet Interface..............................72 Configuration, Management and Alarms.......................72...
  • Page 70: E1 Interface

    Model 1195 Getting Started Guide A • Specifications E1 Interface • Electrical Interface: E1 • Channel capacity: Up to 8E1 • Bit rate: 2.048 Mbps + 50 ppm • Line code: HDB3 • Frame Structure: As per G.704 • Electrical Interface: As per G.703 •...
  • Page 71: Optical Interface Specifications: 1310Nm Single Mode

    Model 1195 Getting Started Guide A • Specifications Optical Interface Specifications: 1310nm Single Mode Transmitter Optical Characteristics Receiver Optical Characteristics Optical Interface Specifications: 1550nm Single Mode Transmitter Optical Characteristics Optical Interface Specifications: 1310nm Single Mode...
  • Page 72: Receiver Optical Characteristics

    Model 1195 Getting Started Guide A • Specifications Receiver Optical Characteristics Safety • Class 1 Laser • Auto Laser Shut Down in the event of fiber break. Ethernet Interface • 10/100BaseT • Number of Interfaces: 1 • Interface: RJ-45 Ethernet 10BaseT or 100BaseT-TX (auto sensing) •...
  • Page 73: Environment

    Model 1195 Getting Started Guide A • Specifications Environment • Temperature: -5ºC ~ +55ºC for operation • - 40ºC to +70ºC for storage • Humidity: 5% to 95% (35ºC) - non-condensing Physical • Width: 1552 mm • Depth: 434 mm •...
  • Page 74: Connector Pinouts

    Appendix B Connector pinouts Chapter contents DB-37 connector pinout (Model 1195).........................75 DB-37 connector pinout details for E1 connections ..................75...
  • Page 75: Connector Pinout (Model 1195/4E1)

    Model 1195 Getting Started Guide B • Connector pinouts DB-37 connector pinout (Model 1195) Figure 32. DB-37 connector pinout DB-37 connector pinout details for E1 connections DB-37 connector pinout (Model 1195)

Table of Contents