Patton electronics 3046/V24 Installation And Operation Manual

Digital data service multiplexer

Advertisement

Quick Links

Doc #: 138001UA
Part #: 07M3046-A
D
D
S
M
IGITAL
ATA
ERVICE
ULTIPLEXER
3046/V24 & 3046/V35
(CTS DDS-MUX)
I
O
M
NSTALLATION AND
PERATIONS
ANUAL
May 24, 2000
Copyright© 2000 Patton Electronics Co., All Rights Reserved
An ISO-9001
Certified Company

Advertisement

Table of Contents
loading

Summary of Contents for Patton electronics 3046/V24

  • Page 1 Doc #: 138001UA Part #: 07M3046-A IGITAL ERVICE ULTIPLEXER 3046/V24 & 3046/V35 (CTS DDS-MUX) NSTALLATION AND PERATIONS ANUAL May 24, 2000 Copyright© 2000 Patton Electronics Co., All Rights Reserved An ISO-9001 Certified Company...
  • Page 2 Doc #: 138001UA Part #: 07M3046-A IGITAL ERVICE ULTIPLEXER 3046/V24 & 3046/V35 (CTS DDS-MUX) NSTALLATION AND PERATIONS ANUAL Copyright© 2000 Patton Electronics Co., All Rights Reserved An ISO-9001 Certified Company...
  • Page 3: Radio And Tv Interference

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA PROPRIETARY NOTICE The information contained herein is proprietary and confidential to Patton Electronics Co. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is given by Patton Electronics Co.
  • Page 4 3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA This Page Left Blank...
  • Page 5: Table Of Contents

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA Contents CHAPTER 1 - OPERATION Channel Selection Modes ......................... 1-1 Channel Clocking ..........................1-1 Channel Interface ..........................1-1 Front Panel LEDs ..........................1-2 Front Panel LCD and Push Buttons ....................1-2 Loopback Selection ........................... 1-2 Power Supply ............................
  • Page 6: Chapter 1 - Operation

    ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 3046 138001UA CHAPTER 1 - OPERATION The Patton 3046 (CTS DDS-MUX) is a network enhancement accessory intended for use on a high speed synchronous Digital Data Service (DDS) circuit or high speed modem, utilizing Time Division Multiplex (TDM) techniques to share the provided bandwidth. The 3046 (CTS DDS-MUX) is configured at the factory for high speed 64K/56K bps composite operation or low speed 9.6K/14.4K/19.2K bps composite operation.
  • Page 7: Front Panel Leds

    ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 3046 138001UA The V.35 version of the 3046 (CTS DDS-MUX) has the following interface leads implemented on the M34 connector: Chassis (A), TXD (P,S), RXD (R,T), RTS (C), CTS (D), DSR (E), Sig Gnd (B), DCD (F), TXC (Y,AA), RXC (V,X), DTR (H). Front Panel LEDs Front panel LEDs are provided to indicate power is applied, Send Data (SD), Receive Data (RD), In-Sync (SYNC) condition between the two DDS-MUX's and Remote Digital...
  • Page 8: Chapter 2 - Setup And Installation

    V24 (CTS DDS-MUX-V.35) is factory set to high speed (E2 Removed). Disassembly Removal of the cover is not required for operation or configuration of the 3046/V24 (CTS DDS-MUX). Only a factory trained, qualified service technician should ever attempt to remove the cover.
  • Page 9: Installation

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA Installation Select an appropriate location accessible to and within six feet of an AC power outlet. The outlet must have a ground pin receptacle for product warranty. The cabling between each attached device and the 3046 (CTS DDS-MUX) should be "Straight Through", shielded and terminated with male connectors.
  • Page 10: Lcd System Status Display

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA LCD SYSTEM STATUS Display During normal operation the 3046 (CTS DDS-MUX) will be in the display. This display indicates synchronization with the remote end by the message 1 0 1 3 A 0 0 1 If the two 3046s (CTS DDS-MUX) are not in sync, the display will indicate this by displaying dashes where the message is.
  • Page 11: Speed

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA Speed If a mode is selected that does not support the currently configured value or a parameter available in the current configuration, an asterisk will not appear on any value for that particular mode. To select a composite from the display, press the CHN push...
  • Page 12: Mode

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA Mode The mode parameter selects the number of active channels and the maximum speed each active channel can operate. The following chart outlines the rates/channels available for each of the modes. (E2 installed 9.6K,14.4K & 19.2K, E2 Removed 56K & 64K) Composite Speed 9.6K Mode CH 1...
  • Page 13: Remote Digital Loopback

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA Press the VAL push button until the desired value appears. Press STR to configure the 3046 (CTS DDS-MUX) or CHN and PAR to select additional configuration parameters. Changing any Parameter value and pressing the STR for the composite port WILL cause loss of data for all channels.
  • Page 14: Channel Configuration

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA Channel Configuration The channel configuration menus allow the selection of channel speed, mode, number of bits per element in asynchronous mode, CTS delay, Carrier Detect function and Local loopback function. Only channels that are active based on the selected mode in the composite configuration will be displayed.
  • Page 15: Mode

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA Mode The Channel Mode parameter is used to select Synchronous or Asynchronous operation for the channel. Each channel is individually selected for sync / async. Channels must be configured identically on both sides of the link. If Channel 1 is async on the local end, Channel 1 must also be async on the remote end.
  • Page 16: Cts Delay

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA Press the VAL push button until the desired value appears. Press STR to configure the 3046 (CTS DDS-MUX) or CHN and PAR to select additional configuration parameters. Changing any Parameter value and pressing the STR for the channel port WILL cause loss of data for that channel.
  • Page 17: Local Digital Loopback

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA To select a channel (Carrier Detect Source Select) from the display, press the CHN push button until the desired channel appears and the PAR push button until the following LCD display appears: 1 0 1 3 A 0 0 3 Press the VAL push button until the desired value appears.
  • Page 18: Appendix

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA APPENDIX RD(A) RT(A) RD(B) RT(B) TD(A) TT(A) TD(B) TT(B) M-34 / V.35 Composite Interface Pins Supported Channel Interface Pins Supported PPENDIX...
  • Page 19: Technical Specifications

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA TECHNICAL SPECIFICATIONS Applications Front Panel Multiple Sync or Async Terminals Indicators: .. Power, Send Data, Receive sharing one DSU/CSU or modem link Data, Remote Digital Loop, Sync, Configuration LCD Capacity Switches: ... Channel, Parameter, Value, Store Six RS-232 Sync/Async DTE devices One RS-232 or V.35 DCE Master...
  • Page 20: Command Tree

    3046 ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 138001UA Button Loop SYSTEM Composite Channel STATUS SYNC LOOP 19.2 14.4 Button SPEED SPEED 19.2 Loop Button MODE MODE Loop LP-BK CHR-LEN CTS-DL CD-SEL LP-BK Command Tree T I M E DI V I SI O N D D S MU X M UL T I P L E X E R C H N...
  • Page 21 7622 Rickenbacker Drive Gaithersburg, MD 20879 Sales: 301 975-1000 Support: 301 975-1007 Web Address: www.patton.com...