Service Bulletin 4812 713 40300

AUTHOR: Jürgen Reinhardt
Last Update: 06/02/08
VERSION: 1.2
TITLE: Insufficient Drying Performance Condensation Drier with dual coil heater 2x1300W, Tiny Domino Controls.
SUBJECT:
REMEDIAL ACTION
Upgrade of controls in production since week 12/2008. This modification is improving the performance in automatic drying
programs. Please re-program controls with SAM by using the latest data base version 62.
All Tiny controls built before week 40 / 2007 are not programmable by SAM, these controls must be replaced by new
ones.
All concerned spare parts in the warehouse have been replaced by the latest version of controls. Furthermore all the
service 12NC of Tiny controls built before week 40 / 2007 have been substituted as well.