Whirlpool W10301482B Tech Sheet page 2

Table of Contents

Advertisement

TECH SHEET - DO NOT DISCARD
Power button controls "Sensing"
and "Done" indicators.
Figure 1. Console Diagnostics.
DIAGNOSTIC: Displaying Inlet Air Flow
Used to display the air flow value at the inlet of the heater box being measured by
the machine control.
After all saved fault codes have been displayed, press the Wrinkle Shield button
to activate air flow detection. A 30 or 50 second countdown timer will start and the
dryer will turn on.
➔ If the dryer is cold, the countdown will start at 50 seconds.
NOTE: If the dryer is extremely cold (less than 40°F [4.4°C]), the air flow may
not be detected properly, and "--" will be displayed.
➔ If the dryer is hot, the countdown timer will start at 30 seconds (cool down
period) followed by an additional 50 second countdown.
A Dryness Level modifier LED will also be illuminated to indicate the air flow
range corresponding to the number displayed.
The More LED will be illuminated for air flow readings above 40 cfm.
The Normal LED will be illuminated for air flow readings between 29 and 40 cfm.
The Less LED will be illuminated for air flow readings less than 29 cfm.
➔ If air flow value is low, check to make sure the lint screen is clean, the door
seal is in place, and the vent is not obstructed.
DIAGNOSTIC: Displaying Line Voltage
Used to display the line voltage currently being measured by the machine control:
After all saved fault codes have been displayed, press the Cycle Signal
button. The last 2 digits of the voltage value will be displayed on the dual
7-segment display.
A Dryness Level modifier LED will also be illuminated to indicate the voltage range
corresponding to the number displayed. The Dryness Level LEDs relate to specific
voltage ranges as follows:
The More LED will be illuminated for high voltage readings (above 260 VAC).
The Normal LED will be illuminated for normal voltage readings (200-260 VAC).
The Less LED will be illuminated for low voltage readings (below 200 VAC).
➔ If the line voltage is not seen on L2, the display will flash
Go to TEST #1, page 4.
DEACTIVATING THE DIAGNOSTIC TEST MODE
Press the Power button twice to exit diagnostics.
F
O
R
S
E
R
V
I
C
E
T
E
C
H
N
I
C
Rotating the knob turns indicators
on or off.
L 2
.
I
A
N
S '
U
S
E
O
N
L
Y
Drum Light
button controls
its own indicator.
"Less Time"
"More Time"
Dryness Level
button turns
button turns
button controls
the right digit
the left digit
all indicators
of the display
of the display
above button.
on or off.
on or off.
ACTIVATING THE MANUAL LOAD TEST
1. Be sure the dryer is in standby mode (plugged in with all indicators off, or with
only the Done indicator on).
2. Select any one button (except Power) and follow the steps below, using the
same button (remember the button):
Press/
Release
hold 2-5
for 2-5
seconds
seconds
flashes momentarily, the motor starts right away, and the Heavy Duty LED
88
flashes (this step starts the Manual Load sequence):
1. Turn on motor.
Now press any key (except Power) and the control will advance through each step
of the following sequence:
Non Steam Model
2. Motor + heater.
3. No loads on (motor + heater).
4. Repeat using same button.
Steam Model
2. Motor + heater + water valve.
Motor + heater + water valve +
3.
drum light.
No loads on (motor + heater +
4.
water valve).
5. Repeat using same button.
DEACTIVATING THE MANUAL LOAD TEST
Press the Power button to exit this mode.
Start button
turns on the
dryer.
Temp button
Wrinkle Shield
button controls
controls all
its own
indicators
indicator.
above button.
Press/
Release
Press/
hold 2-5
for 2-5
hold 2-5
seconds
seconds
seconds
Flash "Heavy Duty" LED.
Flash "Casual" LED.
Flash "Normal" LED.
Start sequence again at 1.
Flash "Delicate" LED.
Flash "Drum Light" LED.
Flash "Normal" LED.
Start sequence again at 1.
P
A
R
T
N
O
PAGE 2
Cycle Signal
button controls
the Eco Monitor
LEDs.
Damp Dry Signal
button controls
all indicators
above button.
Release
Press/
for 2-5
hold 2-5
seconds
seconds
.
W10301482B

Hide quick links:

Advertisement

Table of Contents
loading