Electrical Adjustments
Group/
Item Name
Item
5 Eco Fan Max
6 Eco Fan3 Min
7 Eco Fan3 Max
Plc-xr251
Group
Fan tem error Setting (Memorized)
253
0 Temp A Warning (High)
1 Temp B Warning (High)
 Temp C Warning (High)
3 Temp B-A Warning(High)
4 Temp C-A Warning(High)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal)
9 Temp C-A Warning(Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
1 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
Temp A Warning Offset
0
(Time)
1 Temp B Warning Offset
(Time)
 Temp C Warning Offset
(Time)
3 Temp B-A Warning Offset
(Time)
4 Temp C-A Warning Offset
(Time)
Plc-xr251
Group
Fan control range Setting (temp./Voltage)
254
0 High Fan Control Min Temp
1 High Fan Control Max Temp
 High Fan1 Min
3 High Fan1 Max
4 High Fan Min
5 High Fan Max
6 High Fan3 Min
7 High Fan3 Max
10 Normal Fan Control Min
Temp
11 Normal Fan Control Max
Temp
1 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan Min
15 Normal Fan Max
16 Normal Fan3 Min
17 Normal Fan3 Max
0 Eco Fan Control Min Temp
1 Eco Fan Control Max Temp
 Eco Fan1 Min
3 Eco Fan1 Max
4 Eco Fan Min
5 Eco Fan Max
6 Eco Fan3 Min
7 Eco Fan3 Max
Group
Fan Start/cooling Setting
255
0 Fan1 Initial Volt
Function
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Temp. C to judge the Temp Error at
Normal (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at Eco
(Room)
Temp. B to judge the Temp Error at
Eco(Panel)
Temp. C to judge the Temp Error at
Eco(Panel)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Temp Senser Control Start/End Tem.p
at Normal
Fan voltage value at Normal (unit: 0.1V)
Temp Senser Control Start/End Tem.p
at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan voltage value at Eco (unit: 0.1V
Fan Start Voltage(0.1V)
Initial
65
70
75
80
55
60
75
75
110
110
115
115
Normal Ceiling HiLand-
HiLand-
Normal
Ceiling
44
44
4
41
55
54
54
54
59
59
58
58
100
100
100
100
100
100
100
100
43
43
41
41
55
54
53
53
58
58
57
57
100
100
100
100
100
100
100
100
43
4
41
40
54
53
5
5
57
56
55
55
100
100
100
100
100
100
100
100
3
3
3
3
3
HiLand-
HiLand-
Normal Ceiling
Normal
Ceiling
3
31
33
3
41
41
38
38
78
80
95
100
135
135
135
135
75
85
85
95
100
105
110
115
80
85
100
105
135
135
135
135
33
3
33
3
40
40
38
38
68
75
95
100
135
135
135
135
73
83
94
106
99
104
13
18
75
80
100
105
135
135
135
135
3
3
3
31
40
39
38
37
5
60
75
80
10
10
15
15
50
55
60
65
65
70
75
80
55
60
75
75
110
110
115
115
55
-47-
range Note
0-55
0-55
0-55
-
-
-
-
-
30-100
30-100
30-100
0-100
0-100
30-100
30-100
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
-
-
-
-
-
-
-
-
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-100
0-100
0-55
0-55
0-55
0-55
0-55
0-55
0-55