Mechanical Disassembly
b Power board, Fan(FN002) and Filter removal
1. Remove the Power board spacer sheet.
. Remove  screws A(M3x8) and  screws B(M4x6) to remove the Power shield.
3. Remove the thermal switch(SW601). Remove 6 screws C(T3x8) to remove the Power board
holder and the fan(FN00).
4. Remove screw D(T3x8) to remove the Power board.
5. Remove 3 screws E(T3x8) to remove the Lamp Ballast.
6. Remove the Panel net front and Panel net back.
Note:
Please pay attention to the install
direction of SW601, the side with
text facing to the projector back.
Power board
spacer sheet
A (M3x8)x
Power shield
C
C(T3x8)x6
SW601
Power board holder
E
Power board
D(T3x8)
Panel net front
A
C
C
C
C
The exhaust side facing
to the screening shield.
FN00
Lamp Ballast
E
E(T3x8)x3
B (M4x6)x
B
Panel net back