Click "Test" to test your email settings.
3.7 PTZ Setup:
*Note: To control the PTZ, You must connect the wires to the RS-485 port on the back of the DVR
Channel: Choose which camera view you want to work with.
Protocol: Choose the "protocol" required for your device. Both protocols require an
additional RS-485 data cable.
Device ID: Assign an ID number to each channel (camera view).
Baud rate: We suggest using a "baud rate" no higher than 9600 to avoid errors. Please refer to
your cameras specifications for the baud rate that is best for your device.
Tour position list: This is where you set up each camera "tour". First, highlight the line in
which you want to add your preset, then click the box with the question mark. Use this box to
position the camera to the desired view, then click store. You then need to assign how you
want each position to hold by selecting "keep time". If you change a preset, simply click
"update" after you are done reconfiguring. To delete a preset, highlight the tour you want to
delete and click "remove".
To run your tour use your mouse and right click to select "PTZ control" key then click "go
to" after checking "√" the "tour start" box
*Note: You can set up to 32 presets to play back to back