Lamp Replacement - Sanyo PLC-SW30 Service Manual

Hide thumbs Also See for PLC-SW30:
Table of Contents

Advertisement

■ Lamp Replacement

WARNING:
- Allow a projector to cool, for at least 45 minutes before you open Lamp
Cover. The inside of a projector can become very hot.
- For continued safety, replace with a lamp assembly of the same type.
- Do not drop a lamp assembly or touch a glass bulb! The glass can
shatter and may cause injury.
Procedure
1
Turn off the projector and disconnect the AC plug. Allow the projector to
cool at least for 45 minutes.
2
Remove 1 screw and remove the lamp cover.
3
Remove 2 screws and pull out the lamp assembly by grasping the han-
dle.
4
Replace the lamp assembly securely and tighten 2 screws.
5
Close the lamp cover and tighten 1 screw.
6
Connect the AC Power Cord to the projector and turn on the projector.
7
Reset the Lamp Replace Counter, see below explanation.
Note:
- Do not reset the Lamp Replace Counter, except after lamp is replaced.
- The projector can not be turned-on with lamp cover removed, because
when the lamp cover is removed, the lamp cover switch is also released
to switch off the mains power for safety.
How to reset Lamp Replace Counter
1
Turn the projector on, and press the MENU button
and the on-screen menu will appear.
POINT LEFT/RIGHT buttons to move the red frame
pointer to the Setting Menu icon.
2
Press the POINT DOWN button to move the red
frame pointer to "Lamp counter reset" and then press
the SELECT button. The message "Lamp replace
counter reset?" is displayed. Move the pointer to [Yes]
and then press the SELECT button.
3
Another confirmation dialog box appears and select
[Yes] to reset Lamp Replace Counter .
Please refer to the owners manual for further informa-
tion.
How to check Lamp used time
The LAMP REPLACE indicator will light yellow when
the total lamp used time reaches 2000 hours. This is
to indicate that lamp replacement is required.
The total lamp used time is calculated by using the
below expression;
Total lamp used time = T
T
: used time in the Eco mode
eco
T
: used time in the Normal and Auto mode
normal
You can check the lamp replace counter following to
below procedure.
1
Press and hold the POWER ON-OFF button on the
projector or the remote control unit for more than 20
Press the
+ T
l (1+1/4)
eco
noma
ORDER REPLACEMENT LAMP
Type No.
POA-LMP57
Recommendation
Should the air filter become clogged with dust particles,
it will reduce the cooling fan's effectiveness and may
result in internal heat build up and short lamp life. We
recommend cleaning the air filter after the projection
lamp is replaced.
Refer to "Air Filter Cleaning".
seconds.
2
The projector used time and lamp used time will be
displayed on the screen briefly.
Counter
Projector
Lamp
Normal
Total
Total lamp used time
-7-
Service Parts No.
610 308 3117
Screw
Lamp cover
Handle
Screws
Lamp Assembly
Projector used time
130H
24H
Eco
100H
130H

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents