Troubleshooting

Start your trouble shooting with the following actions
Possible power problem
Make sure power is connected. If you switch the monitor off and then back on, the diode on
the front should show green light. Some models have a main power switch next to the power
inlet check that this is set to on. If you have a model without power adapter and still the no
green light it's not a power problem.
If not, check your power connection to the 12V/24V adapter and to the wall. There is a
similar diode on the 12V/24V adapter that should show green light.
• If not, the adapter might be broken. If you have another adapter of the same type you
can verify by using that adapter.
• If yes, there is a problem with the panel which should be repaired.
If yes, then it is not a power problem.
Possible signal problem
If picture is not stable or not shown at all or you get "No Sync" then check connection of the
signal cable and graphic board settings.
If cable connections and graphic board settings are OK, then try the following
Switch monitor off. Wait 10 seconds and switch it back on
Re-boot the PC
Test monitor by connecting it to another PC
If nothing of this helps, then there is something wrong with the monitor and it should be
repaired. Contact your local reseller for assistance.
29