SECTION 3: PREPARE THE DOOR

3-1
FIG.3
FIG.5
LOCATING
VERTICAL C L
3-2
a. Mortise the Door edge for the Lock Case to the dimensions shown on the
Template. Insert the Lock (with Face Plate) in Mortise. CAUTION: Do not pinch the
Motor Wires.
CAUTION: Drill the holes only halfway through the Door from each side.
b. Align the top of the Face Plate with the reference mark and scribe the Face Plate
outline as illustrated in Fig.8. Mortise to the front thickness.
c. Drill the required side holes through the outside and inside faces of the Door.
a. Draw a horizontal centerline on both sides and edge of the Door
at the desired Knob Center Height Refer to Fig. 3.
NOTE: If the Frame has already been prepared for a Falcon Strike,
install the Strike and use the Strike Lip as a reference to locate the
horizontal centerline position.
bottom of the Strike Lip as illustrated in Fig. 4 and draw horizontal
centerlines on the Door at this position as illustrated in Fig. 3.
b. Using the Backset Locator furnished, mark two points on each
side of the Door, above and below the horizontal line. Refer to
Fig.5. Draw a vertical line through the two points on each side
of the Door.
c. Separate the Door Edge Template from the Door Surface
Template. Position the correct side of the Door Surface
Template on the outside face of the Door, aligning the Locator
points with the horizontal and vertical lines drawn on the Door
as illustrated in Fig. 6.
CAUTION: Spot only those holes required for the Lockset being
installed, and mark the Strike Lip position on the Frame.
d. Using the opposite side of the Template, position on the inside
face of the Door aligning locator points with the horizontal and
vertical lines drawn on the Door and spot the required holes.
e. Center the Door Edge portion of the Template on the Door edge
and align the horizontal Locator points with the horizontal line
drawn on the Door. Mark the top and bottom points of the Case
Mortise and the Face Plate top reference as illustrated in Fig. 7.
MARK FACE
PLATE TOP
REFERENCE
FIG.7
Mark the Door 3/16" below the
MARK STRIKE LIP
POSITION ON FRAME.
NOTE: BOTTOM OF LIP
IS 3/16" ABOVE
HORIZONTAL C L
LOCATING POSITION OF
HORIZONTAL CENTERLINE
WHEN FRAME HAS BEEN
PREPARED FOR STRIKE
3/16"
FIG.4
FIG.6
ALIGN WITH
REFERENCE
MARK
SCRIBE
FACE
OUTLINE
FIG.8