Notes:
If the Green LED flashes only once, the confirmation signal did not match the Load signal.
Repeat from (a).
If the Yellow LED does not flash to acknowledge storage, the identity number is already
stored in the memory.
The POWER LED will turn off during the loading routine.

4.3 Delete Transmitter Identity

(a)
With either CLEAR or TEST mode selected:
(b) Depress and hold the internal transmitter DELETE switch.
(c)
Select RESET mode using the key switch. The Green Local LED will flash.
(d) Release the DELETE switch. The MEMORY is now open for deleting the ident number.
(e)
Activate a transmitter, using a Local activation. If the ident is accepted the Red Alarm
LED will flash asking for confirmation and a long bleep will be heard.
(f)
Activate a transmitter again, using a Local activation. If the confirmation is accepted 3
short bleeps will be heard and the Yellow Low Battery LED will flash to acknowledge
deletion.
(g) Repeat from (a) for each transmitter ident to be deleted.
Notes:
To delete a specific transmitter number the transmitter must be available and routine 4.3
used. When a transmitter is lost, the 7703's Memory must be cleared using routine 4.1 and
the transmitter serial ident number re-loaded using routine 4.2.

5. User Instructions

5.1 Instructions

Though the 7703 has many features it is very easy to use. Any of the visual indicators can
be accompanies with an audible warning but these would normally be selected at the time of
installation.
The only user control is the key switch.
transmitters whose identity numbers have been stored in it's memory. The identity numbers
will remain safely stored in the memory, even in the event of total power failure.

5.2 Audible Warning

5.2.1 Audible warning can be selected to accompany any of the visual indicators in addition,
special selections can be made as follows :
5.2.2 Five second delay of warning.
5.2.3 Clear mode not set, bleeps 3 times every 2 minutes. Any of the above selections are best
made and initialised at the time of commissioning. These are made using the internal
switches.
The 7703 will only recognise the
7703 INSTALLATION, ISSUE V2.2 – 13/04/10