5.4.1

Fuses and ratings

TO PREVENT SHOCK HAZARD, THE Titan HARDWARE SHOULD ONLY BE
OPENED BY QUALIFIED PERSONNEL. REMOVE THE POWER LEAD FROM THE
UNIT BEFORE REMOVING THE TOP COVER.
Fuse locations and ratings are as follows:
FUNCTION
Mains
Note that no fuses or any other user-serviceable parts or options are located inside the Titan
unit.
5.5

Stand-alone operation

It is possible to operate Titan without a connection to a host computer. This is done by setting up the
unit as required using the Titan Control Panel app whilst it is connected to a host computer via its
USB interface, then placing the unit in standby by pressing the standby button, before disconnecting
the unit from the host and power source. When the unit is re-powered, and detects that no USB
connection is active, it reloads the settings which were previously stored.
Since all of the outputs have optional mixers within the Titan hardware whose inputs include all of
Titan's input connectors, it is possible, for example, to connect the digital input pair to one or more
analogue output pairs, and to connect the analogue input pairs to the digital output pair. The
synchronization source and sample rate can be set in the usual way. Thus stand-alone mode can be
used to configure a stand-alone D/A converter and A/D converter, with static mixing if required.
NOTE: If, during stand-alone operation, Titan is set to use an external synchronization source,
i.e. DI, Wordclock or ADAT (only available in ADAT modes), then the sample rate is
automatically changed to follow the sample rate of the external synchronization source. If the
designated synchronization source is not connected, the sample rate reverts to local sync at
the selected sample rate.
5.6

Rack mounting

Titan is supplied configured for table-top operation, with rubber feet attached and no rack-mount ears
fitted.
To convert for rack-mounting: First fit the rack-mount ears by removing the front four screws from
each side of the unit, using the hex key provided; then replace the same screws to retain the rack
ears. If necessary, the rubber feet can be removed by withdrawing the plastic centre-hub of each foot
a little way prior to pulling the whole foot out. The hub can be initially raised with a small flat-bladed
screwdriver. Retain the feet for later use.
If Titan units are rack mounted, an empty 1U gap should be left above each Titan to ensure effective
cooling.
© 2013 Prism Media Products Ltd
Operation Manual
LOCATION
Rear panel
500mA(T), 20mm, glass