2. Loosen the three screws surrounding the outer drum
housing. (The screws do not need to be completely
removed). Remove the drum cover.
3. Pull the entire drum out of the machine.
4. Flip the drum over and remove the three outer-most
screws from the drum. (Figure 14)
5. Pull out the inner drum and disconnect the cable.
Push the end back into the drum.
6. Face the drum towards the floor. Starting with the
auger end of the cable, pull the cable out completely
through the front of the drum.
Figure 14 – Removing Screws From Drum
7. Feed the end of the new cable back through the
nose of the outer drum and then attach it to the inner
drum (Figure 15) . Use the illustration on the inner
drum as a guide for which direction to start the cable.
Figure 15 – Attaching Cable To Inner Drum
8. Replace inner drum back in outer drum. Put the sec-
tion of the inner drum with the cable attached into the
outer drum first. Push the rest of the inner drum into
place. Line up the three screw holes and replace
the screws.
Clutch Retention Screw
Clutch Adjustment
Screw
Inner Drum
Auto-Clean™ Drain Cleaning Machine
9. Flip the drum over and manually feed the cable back
into the drum. (Figure 16)
Figure 16 – Feeding Cable Into Drum
10. Place the machine on its end and place the drum
back on the machine (Figure 17) . Spin the drum until
it falls into place.
Figure 17 – Inserting Drum Into Machine