Microprocessor Control; Wireless Remote Controller - Mitsubishi Electric MS-18NV Service Manual

Table of Contents

Advertisement

8

MICROPROCESSOR CONTROL

WIRELESS REMOTE CONTROLLER

Signal transmitting section
Operation display section
OPERATE /STOP
(ON /OFF)button
OPERATION SELECT button
FAN SPEED CONTROL button
SLEEP button
ON-TIMER button
CLOCK SET button
HR. button
MIN. button
(TIME SET button)
INDOOR UNIT DISPLAY SECTION
Operation Indicator lamp
The operation indicator at the right side of the indoor
unit indicates the operation state.
Operation Indicator
Indication
Operation state
This shows that the
air conditioner is
operating to reach
the target temperature.
Please wait unitil the
target temperature is
obtained.
This shows that the
room temperature is
approaching the
target temperature.
MS-18NV -
Once the operation mode are set, the same operation mode
can be repeated by simply turning the
OPERATE/STOP(ON/OFF) button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to
protect system from overload and compressor will not restart
for 3 minutes.
8-1. "I FEEL CONTROL" (
(1) Press OPERATE/STOP(ON/OFF) button on the remote
TEMPERATURE buttons
(2) Select "I FEEL CONTROL"(
VANE CONTROL button
(3) The operation mode is determined by the room
SWING buttons
OFF-TIMER button
RESET button
Example
Previous operation
lighting
COOL mode of
"I FEEL CONTROL" or
COOL mode
not lighting
Difference
betweeen set
temperature
and room
temperature
Example
About 2 :
or more
Previous operation
COOL mode of
"I FEEL CONTROL"
or COOL mode
About 2 :
or less
10
E4
controller. Operation Indicator lamp of the indoor unit
turns on with a beep tone.
OPERATION SELECT button.
temperature at start-up of the operation.
Initial room temperature
25: or more
more than 13:,
less than 25:
Once the mode is fixed, the mode does not change by
room temperature afterwards.
Under the ON-TIMER (
determined according to the room temperature as the
operation starts.
When the system is stopped with the
OPERATE/STOP(ON/OFF) button on the remote
controller, and restarted within 2 hours in "I FEEL
CONTROL" (
) mode, the system operates in previous
mode automatically regardless of the room temperature.
When the system is restarted after 2 hours and more,
the operation mode is determined by the room
temperature at start-up of the operation.
) OPERATION
) mode with the
mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
) operation, the mode is
Restart
COOL mode of
"I FEEL CONTROL"
Restart
COOL or DRY mode of
"I FEEL CONTROL" that
determined by room
temperature at start-up
of the operation.

Hide quick links: