Desa A Series Owner's Operation And Installation Manual page 9

Unvented (vent-free) propane/lp gas fireplace, variable manuallycontrolled "a" models and thermostaticallycontrolled “c” models with split oak logs
Table of Contents

Advertisement

INSTALLATION
Continued
6. Plug in blower power cord.
a. If your fireplace system is installed
as a freestanding unit with an ac-
cessory mantel, determine whether
the power cord will exit the left side
or the right side of the firebox. In-
stall 1 plastic bushing provided into
the 1.5" hole in the floor support
bracket on the exit side (see Figure
11). Install the second plastic bush-
ing provided into the 1.5" hole in the
outer casing through which the
power cord will exit. Route power
cord through both plastic bushings
and plug the power cord into a prop-
erly grounded 3-prong wall recep-
tacle near the firebox.
b. If your fireplace system installa-
tion is recessed, plug the power cord
into a properly installed duplex out-
let. (If an outlet is not available, the
Vanguard accessory model GA3555
Outlet kit with/ cover can be installed
in your fireplace which will supply
a convenient 3-prong grounded elec-
trical outlet for your blower. Refer
to the installation manual provided
with the model GA3555 accessory
for instructions on wiring the duplex
outlet.)
7. Check to make sure that the power cord
is completely clear of the blower wheel
and that there are no other foreign ob-
jects in blower wheel. Turn blower on
and check for operation. Turn blower
off by rotating knob fully counterclock-
wise before continuing.
WARNING: Never touch the
blower wheel while in operation.
8.
Peel off the backing paper and stick the
supplied wiring diagram decal on the fire-
box bottom approximately 3" to the right
of the blower speed control (Figure 12).
104410
9. Replace log base assembly in fireplace.
Feed flexible gas supply line into fire-
place base area while replacing log base
assembly. Make sure the entire flexible
gas line is in fireplace base area.
Note: If firebrick is installed, make
sure the back of the firebox bottom
slides under the rear panel of the fire-
brick. (lift the firebrick up if necessary.)
CAUTION: Do not pick up log
base assembly by burners. This
could damage burners. Only
handle base by grates.
10. Reattach log base assembly to fireplace
with screws removed in step 1.
Note: Discard the remaining hardware items.
WARNING: Failure to position
the parts in accordance with sup-
plied diagrams or failure to use
only parts specifically approved
with this heater may result in dam-
age or personal injury.
Right Floor
Support
Bracket
Figure 11 - Installing Plastic Bushing for
Power Cord
9
OWNER'S MANUAL
Wiring
Diagram
Never attempt to service heater while it is plugged in,
operating, or hot. Burns and electrical shock could
result. Only a qualified service person should service
or repair heater.
If any of the original wire as supplied with the appliance must be
replaced, it must be replaced with 105°C wire or it's equivalent.
110/115
V.A.C.
120 Vac. 60 Hz. . 78 Amps
DESA International, Bowling Green, KY
Figure 12 - Location of Wiring Diagram Decal
3" from Blower
Plastic
Bushing
WARNING
WARNING ICON
G 001
Variable
Fan Switch
Off
On
Blower
Motor
Black
Black
White
White
Green
101584-05