Download Print this page

Natek ML314B User Instruction page 2

Ml314b-series 4-channel battery charger multi chemistry (platform)

Advertisement

Battery adapters and power supply cables
It is strongly forbidden to make any special supply cables.
The AC and DC supply cables delivered with the charger
are the only power supply cables allowed to be used.
NOTE: Never connect the charger without using a properly connected fuse. 8 A slow, 5x20
mm (T8AL-250V).
INDICATIONS
The charger has one red lamp and four (one per channel) green lamps.
Red continuously on.
Green continuously on.
Green flashes.
Red flashes slowly.
(Green lamps are off)
Red flashes quickly.
(Green lamps are off)
Red and corresponding Green flashes quickly.
42406302.doc
Battery adapter with 4 battery slots (with straps for
securing battery from vehicle movement)
Battery adapter with 4 charging cables
DC supply cable and AC supply cable
(different lengths and plugs available)
DC supply cable: Fuse replacement:
This connector will fit in the most frequent cigarette lighter connectors and in a
standard female 12 mm connector. The positive terminal is connected to the centre
pin. The fuse 8 A slow, is located inside the universal power connector. When
replacing the fuse, unscrew the red plastic knob that surrounds the centre pin. If the
charger is connected to wrong polarity the fuse will break.
2008-10-17
Charger powered (Red lamp is turned
off when first battery connected).
Battery being charged.
Battery fully charged.
Too high or to low supply voltage; or
too high internal temperature; or
internal charger fault.
The battery adapter is not recognized
by the charger. It is not possible to use
the charger without battery adapter.
Battery fault. Remove battery.