Roper Microwave Hood Combination Installation Instructions Manual page 4

Microwave hood combination

Advertisement

This microwave oven is shipped with
the blower assembled for ventless
(recirculating) installation. Adjustments
must be made for roof-and wall-venting
installation. Follow these instructions for
preparing your microwave oven for the
type of venting method you need.
Now start...
with microwave oven in kitchen.
1
Remove shipping materials and
. parts from inside microwave oven.
For all installations:
Floor Damage
Slide range onto cardboard
or
hardboard
before moving across floor.
Failure to do so may damage
floor
covering.
e. Reattach the blower plate to
microwave oven with the six,
blower-plate screws.
2
Disconnect and move a
. freestanding range out of the
cabinet opening to provide easier
access to the upper cabinet and back
wall. Put a thick, protective covering
over a cooktop, set-in range or
countertop to protect from damage
and dirt.
a. Remove the three screws from the
grille on the top front of the microwave
oven. Remove the grille. Set grille and
screws aside.
- -
rod retainer
-
-
screw
3
d
on top of tab for
proper venting
f. Align the damper/duct connector
with the vent on top of the microwave
oven. Damper should be on top of tab.
Use two tapping screws (bright-colored)
to attach damper/duct connector to the
microwave oven.
b. Loosen rod retainer screws and
remove wall mounting plate from the
rear of the microwave oven.
Wall-vented installation:
u
Roof-vented installation:
0
a. Remove and save the six, blower-
plate screws and blower plate.
b. Carefully pull the blower unit out of
the microwave oven, slipping wires out
of clips.
a. Remove and save the six, blower-
plate screws and blower plate.
b. Carefully
pull
the blower unit out of
the microwave oven.
3
Using a plumb line and measuring
n
tape, determine and clearly mark a
vertical center line on the wall in the
area the microwave oven is to be
installed. Find and mark the location
of the wall stud(s) on the wall; then
measure and mark their location on the
wall template. If one wall stud cannot
be found in the
area
where the
microwave oven is to be installed,
consult a local building contiactor. Do
Not attempt to install microwave oven if
a wall stud cannot be found.
c. Rotate blower
/h%Lda+-\
4
Center wall template in opening
n
by lining up the plumb line on
wall with center line on wall template.
Make sure the minimum width is 30
inches and that the top of the wall
template is located a minimum of 30
inches above the cooking surface.
Securely tape or tack the wall template
to the wall.
Note :
. If cabinets are not plumb, adjust the
wall template to the cabinets.
. If front edge of cabinet is lower than
the back edge, adjust the wall
template so that it is level with the
cabinet front.
unit end over
end.
Rotate the
unit 180" so that
the exhaust
c. Rotate blower unit l/4 turn so that
the exhaust ports face the top of the
unit.
ports
face the
rear of the unit.
\
Slip wires into clips
at the upper left hand
comer bi blower unit.
d. Place blower unit back into
microwave oven.
d. Place blower unit back into
microwave oven.
e. Reattach the blower plate to
microwave oven with the six, blower-
plate screws.
Panel C