Samsung RD060PHXEA Installation Manual page 33

Air to water heat pump
Hide thumbs Also See for RD060PHXEA:
Table of Contents

Advertisement

Power Wiring and Communication Wiring Configuration
Be sure to run the power supply cable and the communication cable through electrical conduit as
seen in the picture.
Install the communication cable, indoor power cable and the main power cable in the cable tube.
Secure the cable tube to the outdoor knockout using the CD connector and bushing.
Arrange the cables as shown in the picture.
The diameter of the 6 knock-out holes is
Communication cable
Main power cable
Make a knockout hole by driving in a nail.
When installing the cables through the knockout hole, remove all burrs and protect them
with the protection tape.
Apply rust resisting paint around the hole.
RD060PHXEA_IM_E_32352A(2).indd
27.8 mm.
Ø
33
(Inside)
(Outside)
33
E-
2010-07-26
ソタネト 2:20:02