Bosch 830 ES Manual page 13

Temperature modulated with electronic ignition suitable for heating potable water and space heating (intended for variable flow applications)
Table of Contents

Advertisement

Calculation example for 3" venting:
Exhaust
System used
Number of 90° elbows needed:
Number of 45° elbows needed:
Table 11
Calculation of example
Max. length
90° elbow reduction
sub-total =
45° elbow reduction
Total =
Table 12
For this example, the maximum allowable exhaust pipe
length is 23,5 feet.
Combustion air
System used
Number of 90° elbows needed:
Number of 45° elbows needed:
Table 13
Calculation of example
Max. length
90° elbow reduction
sub-total =
45° elbow reduction
Total =
Table 14
For this example, the maximum allowable combustion
air pipe length is 22,25 feet.
830 ES
Calculation example for 4" venting:
Exhaust
Concentric
1
2
Table 15
28,5'
- 2,5'
26'
- 2,5'
23,5'
Table 16
Combustion air
Concentric
2
1
Table 17
28,5'
- 5'
23,5'
- 1,25'
22,25'
Table 18
System used
Number of 90° elbows needed:
Number of 45° elbows needed:
Calculation of example
Max. length
90° elbow reduction
sub-total =
45° elbow reduction
Total =
For this example, the maximum allowable exhaust pipe
length is 57,25 feet.
System used
Number of 90° elbows needed:
Number of 45° elbows needed:
Calculation of example
Max. length
90° elbow reduction
sub-total =
45° elbow reduction
Total =
For this example, the maximum allowable combustion
air pipe length is 58,5 feet.
Installation instructions | 13
Twin pipe
2
2
61,25'
- 2,5'
58,75'
- 1,5'
57,25'
Twin pipe
1
2
61,25'
- 1,25'
60'
- 1,5'
58,5'
6 720 644 936 (2013/01)