Model Nomenclature - Carrier 50YDV Installation, Operation And Maintenance Instructions

Residential horizontal & vertical packaged geothermal heat pumps
Table of Contents

Advertisement

YE = GT-PG SINGLE-STAGE PURON® REFRIG
YD = GT-PX TWO-STAGE PURON® REFRIG
AIR FLOW CONFIGURATION - ECM:
VERTICAL UPFLOW 50YD/50YE ONLY*
OPTION
RETURN
DISCHARGE
J
LEFT
K
RIGHT
VERTICAL DOWNFLOW
50YD/50YE ONLY*
OPTION
RETURN
DISCHARGE
J
LEFT
DOWN
K
RIGHT
DOWN
HORIZONTAL 50YD/50YE ONLY*
OPTION
RETURN
DISCHARGE
N
RIGHT
LEFT
P
RIGHT
BACK
W
LEFT
RIGHT
Y
LEFT
BACK
NOTE: Some options/configurations not available on all series. Please consult Specification Catalogs for model specific options.
Safety
Warnings, cautions and notices appear throughout this
manual. Read these items carefully before attempting any
installation, service, or troubleshooting of the equipment.
DANGER: Indicates an immediate hazardous situation, which
if not avoided will result in death or serious injury. DANGER
labels on unit access panels must be observed.
WARNING: Indicates a potentially hazardous situation, which
if not avoided could result in death or serious injury.
WARNING!
WARNING! The Puron
Application and Service Manual
®
should be read and understood before attempting to
service refrigerant circuits with HFC-410A.
WARNING!
WARNING! To avoid the release of refrigerant into the
atmosphere, the refrigerant circuit of this unit must be
serviced only by technicians who meet local, state, and
federal profi ciency requirements.
R e s i d e n t i a l P a c k a g e d U n i t s - 6 0 H z P u r o n
Model Nomenclature: General Overview
1
2
3
5
0
Y E V
UNIT TYPE:
SIZE:
018
024
030
036
042
CONFIGURATION:
048
V = VERTICAL UPFLOW
060
H = HORIZONTAL
072
D = VERTICAL DOWNFLOW
AIR FLOW CONFIGURATION - PSC:
VERTICAL UPFLOW
MOTOR
OPTION
RETURN
DISCHARGE
TOP
ECM
L
LEFT
TOP
ECM
R
RIGHT
VERTICAL DOWNFLOW
MOTOR
OPTION
RETURN
DISCHARGE
ECM
L
LEFT
DOWN
ECM
R
RIGHT
DOWN
HORIZONTAL
MOTOR
OPTION
RETURN
DISCHARGE
ECM
Z
RIGHT
ECM
B
RIGHT
BACK
ECM
S
LEFT
RIGHT
ECM
E
LEFT
BACK
4
5
6
7
8
9
10
11
1 2
0
4
L
C
A
3
1
2
REVISION LEVEL:
1 = CURRENT REVISION
VOLTAGE:
3 = 208V, 230V/1PH/60Hz
HEAT EXCHANGER OPTIONS:
MOTOR
TOP
PSC
STANDARD
TOP
PSC
W/HOT WATER GENERATOR
WHOLE HOUSE DEHUMIDIFICATION
WHOLE HOUSE DEHUMIDIFICATION
MOTOR
W/HOT WATER GENERATOR
PSC
PSC
CONTROLS:
C = CXM
MOTOR
NOTE: YEV070 not available with PSC motor
LEFT
PSC
PSC
PSC
PSC
CAUTION: Indicates a potentially hazardous situation or an
unsafe practice, which if not avoided could result in minor or
moderate injury or product or property damage.
NOTICE: Notifi cation of installation, operation or maintenance
information, which is important, but which is not hazard-
related.
WARNING! All refrigerant discharged from this unit must
be recovered WITHOUT EXCEPTION. Technicians must
follow industry accepted guidelines and all local, state,
and federal statutes for the recovery and disposal of
refrigerants. If a compressor is removed from this unit,
refrigerant circuit oil will remain in the compressor. To
avoid leakage of compressor oil, refrigerant lines of the
compressor must be sealed after it is removed.
CAUTION! To avoid equipment damage, DO NOT use
these units as a source of heating or cooling during the
construction process. The mechanical components and
fi lters will quickly become clogged with construction dirt
and debris, which may cause system damage.
R e v. : 4 J a n . , 2 0 1 2
1
PACKAGING:
1 = SINGLE PACK, DOMESTIC
COATED AIR COIL
COPPER
CUPRO-NICKEL
A
J
B
K
R
F
L
M
Rev.: Jan. 4, 2012
WARNING!
CAUTION!
®
3