Kenmore Elite INTELLISOFT 420 SERIES 625.38426 Owner's Manual page 39

With high performance valve
Table of Contents

Advertisement

The faceplate timer (PWA) computer has a self-diag-
nostic function for the electrical system, except for input
power and water meter. The computer monitors elec-
tronic components and circuits for correct operation. If a
malfunction occurs, an error code appears in the face-
plate display.
The chart below shows the error codes that could
appear, and the possible problems for each code.
Error #;
Service Required
See Owner's Manual
Diagnostics
FIG. 62
CODE
Err1, Err3, Err4
Err5
POSSIBLE PROBLEM
MOST LIKELY
_
wiring harness connections
at switch and faceplate
not connected
/ position switch inoperable / motor inoperable
faceplate
timer (PWA)
LESS LIKELY
While an error code appears in the display, all faceplate
buttons are inoperable except the SELECT button.
SELECT remains operational so the service person can
make the MANUAL INITIATED ELECTRONIC DIAG-
NOSTICS (below) to further isolate the problem, and
check the water meter.
PROCEDURE
FOR REMOVING
ERROR
CODE
FROM FACEPLATE:
1. • Unplug transformer from outlet.
• Plug in transformer.
• Wait for 8 minutes.
2. • Unplug transformer from outlet.
• Correct problem.
• Plug in transformer.
• Wait for 8 minutes.
The error code will return if the problem was not corrected.
MANUAL INITIATED ELECTRONICS
DIAGNOSTICS:
1. To enter diagnostics, press the SELECT button once
to go to the Main Menu. Move the black bar to
Service Mode and press Select. Move black bar to
Diagnostics and press Select.
You will see the display, showing valve cycle position,
position switch status (open or closed), and turbine
operation.
TURBINE OPERATION:
If no water is flowing through
the softener, the turbine indicator displays 3 zeros.
When water is flowing, a 000 to 140 count repeats for
each gallon of water passing through the turbine. To
check for positive operation of the turbine if zeros are
shown, open a nearby soft water faucet and observe
the turbine count. If you don't get a reading in the dis-
play, with faucet open, pull the sensor from the valve
outlet port. Pass a small magnet back and forth in front
of the sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing and
check the turbine for binding.
valve position indicator
l0 : 39 : 5_4
l0 : 39 : 56 AM
Pos:
SERVICE
0 : 00
Pos: SERVICE
0 : 00
Req Pos: SERVI(E
Req Pos: SERVICE
Motor:
Off
_
¢_.
Motor:
Off
_9
-(._
Trbn: 00_0
Gals: 0
_,_
Trbn: 126
Gals: 0
I
Days:
1_
Rchgs:()_
I
Days:
1 _
Rchgs:0
_position switch
indicator (open)
turbine count (no
turbine count
water flowing)
(water flowing)
FIG. 63
Questions?
Call The Kenmore
Water Line 1-800-426-9345
39

Advertisement

Table of Contents
loading

Table of Contents