A. TROUBLESHOOTING
MANUAL
ADVANCE
REGENERATION
CHECK
This
check
verifies
proper
operation
of the valve
motor, brine tank fill, brine draw, regeneration flow
rates, and other controller functions. Always make
the initial
checks,
and
the manual
initiated
diag-
nostics.
Notes:
The faceplate
display
must
show a steady
time (not
flashing).
If an error
code shows,
first press
the SE-
LECT button
to enter
the diagnostic
display.
ffi
Press the ON/OFF-HOLD
button
and hold in for
3 seconds.
RECHARGE
begins
to flash
as the
softener
enters
the fill cycle of regeneration.
Re-
move
the brinewell
cover and, using
a flashlight,
observe
fill water
entering
the tank.
a. If water
does
not enter
the tank,
look for an ob-
structed
nozzle,
venturi,
fill flow plug, brine
tubing,
or brine
valve
riser pipe.
CYCLE FLOW RATES (GALLONS PER MIN.)
FILL (flow to salt storage tank)
0.3 (1.1 liters)
BRINING
'_
.13 -.14 (.5 liters)
BRINE RINSE
I
(flow
.1 (.38 liters)
to
1.8 (6.8 liters)
BACKWASH
drain)
FAST RINSE
1.8 (6.8 liters)
ffi
After
observing
fill, press
the ON/OFF-HOLD
button
to move
the softener
into brining.
A slow
flow of water
to the drain
will begin.
Verify brine
draw
from the brine
tank by shining
a flashlight
into
the brinewell
and
observing
a noticeable
drop
in the liquid
level.
Note:
Be sure a salt bridge
is not preventing
water
with
salt contact.
a. If the softener
does
not draw
brine...
...nozzle
and/or
venturi
dirty
or defective.
...nozzle
and venturi
not seated
properly
on gasket.
...restricted
drain
(check
drain
fitting
and hose).
... defective
nozzle
and venturi
seal.
...other
inner
valve
defect
rotor
seal, rotor
& disc,
wave
washer,
etc.).
Note:
If water
system
pressure
is low, an elevated
drain
hose may cause back pressure,
stopping
brine draw.
ffi
Again
press
ON/OFF-HOLD
to move
the soft-
ener into backwash.
Look for a fast flow of water
from the drain
hose.
a. An obstructed
flow indicates
a plugged
top dis-
tributor,
backwash
flow plug,
or drain
hose.
ffi
Press ON/OFF-HOLD
to move
the softener
into
fast rinse, Again
look for a fast drain
flow. Allow
the softener
to rinse for a few minutes
to flush out
any brine
that may remain
in the resin tank from
the brining
cycle test.
To return
the softener
to service,
press
ON/OFF-
HOLD.
BRINE VALVE
, '
FLOAT SETTING
_./float
stop
FREEBOARD MEASUREMENT
(Distance from top of resin tank, to top of resin bed.
FREEBOARD
7"-11"
resin tank
5-4
Problems,