Gas Piping; Venting - Kenmore THE ECONOMIZER 153.333315 HA Owner's Manual

Kenmore water heater user manual
Table of Contents

Advertisement

To
insure proper venting of this gas-fired
water heater, the
correct vent pipe diameter must be utilized.
Any additions or
deletions of other gas appliances on a common vent with this
water heater may adversely affect the operation of the water
heater.
Consult your gas supplier if any such changes
are
planned.
For proper venting in certain installations,
a larger diameter
vent pipe may be necessary.
Consult your local Sears Service
Center or gas supplier to aid you in determining
the proper
venting for your water heater from the vent tables in the current
edition of the National Fuel Gas Code ANSI Z223.1/NFPA
54.
Periodically check the venting system for signs of obstruction
or deterioration
and replace if needed.
The combustion and ventilation air flow must not be obstructed.
The water heater with draft hood installed must be connected
to a chimney or listed vent pipe system, which terminates to
the outdoors.
Never operate the water heater unless it is vented
to the outdoors and has adequate air supply to avoid risks of
improper operation,
explosion or asphyxiation.
For proper draft hood attachment, the draft hood legs may
be angled slightly inward.
Place the draft hood legs in the receiving holes on the top of
the water heater. The legs will snap in the holes to give a
tight fit. Secure two legs to top with sheet metal screws.
Place the vent pipe over the draft hood. With the vent pipe in
position, drill a small hole through both the vent pipe and
draft hood. Secure them together with a sheet metal screw,
see Figure 17.
DRAFT HOOD
VENT 4
_1'
_--%
SCREW F"
I DRA_THOOD
,
,
o ,,T Need
;g°N%%°°e°
All vent gases must be completely vented to the outdoors of the
structure (dwelling).
install only the draft hood provided with
the new water heater and no other draft hood.
Vent pipes must be secured
at each joint with sheet metal
screws.
There must be a minimum of 6 inches (153 ram) clearance
between single wall vent pipe and any combustible
material.
Fill and seal any clearance between single wall vent pipe and
combustible
material
with
mortar
mix, cement,
or other
noncombustible
substance.
For other than single wall, follow
vent pipe manufacturer's
clearance specifications.
To insure
a tight fit of the vent pipe in a brick chimney, seal around the
vent pipe with mortar mix cement.
Failure to have required clearances between vent piping and
combustible
material will result in a fire hazard.
Be sure vent pipe is properly connected to prevent escape of
dangerous flue gases which could cause deadly asphyxiation.
• Flue gases may escape if vent
p_peis not connected
• Do not store corrosive chemicals
in vicinity of water heater.
• Chemical
corrosion of flue and
vent system can cause serious
injury or death.
• Contact
a qualified
installer
or
service agency
Breathing carbon monoxide can cause brain damage
or death Always read and understand instruction manual.
Chemical
vapor corrosion
of the flue and vent system
may
occur if air for combustion
contains certain chemical vapors,
Spray can propellants,
cleaning solvents, refrigerator
and air
conditioner
refrigerants,
swimming
pool chemicals,
calcium
and sodium chloride, waxes, bleach and process chemicals
are typical compounds which are potentially corrosive,
FIGURE17.
Obstructed or deteriorated vent systems may present serious
health risk or asphyxiation.
The vent pipe from the water heater must be no less than the
diameter of the draft hood outlet on the water heater and must
slope upward at least 1/4 inch per linear foot (21 mm per meter).
see Figure 18.
CHIMNEY
im
|
Gas Piping
Fire and Explosion
Hazard
• Do not use water heater with
any gas other than the gas
shown on the rating plate
• Excessive
pressure
to gas
control valve can cause serious
injury or death
• Turn
off gas
lines
during
installation
• Contact
qualified
installer
or
service
agency
FIGURE18.
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents