Wiring - Kenmore THE ECONOMIZER 153.318131 Owner's Manual

Table top electric water heater
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Wiring
CAUTION
J
Never usethis water heater unlessit is completely full of J
water. To prevent damage to the tank and heating ele-
ment, the tank must be filled with water. Water must
flow from the hot water faucet before turn ng on power.
You must provide all wiring of the proper size outside of the
water heater. You must obey local codes and electric company
requirements when you install this wiring.
If you are not familiar with electric codes and practices, or if you
have any doubt, even the slightest doubt, in your ability to con-
nect the wiring to this water heater, obtain the service of a com-
petent electrician. Contact your Sears salesperson to arrange for
a professional electrician.
_,WARNING
WATER HEATERS EQUIPPED
FOR ONE VOLTAGE
ONLY: This water heater is equipped for one type volt-
age only. Check the rating plate near the bottom access
panel for the correct voltage. DO NOT use this water
heater with any voltage other than the one shown on the
model rating plate. Failure to usethe correct voltage can
cause problems which can result in DEATH, SERIOUS
BODILY INJURY,OR PROPERTY DAMAGE. If you have
any questionsor doubts consult your electric company.
_t,CAUTION
If wiring from your fuse box or circuit breaker box was
aluminum for your old water heater, replace it with cop-
per wire. If you wish to reuse the existing aluminum
wire, havethe connection at the water heater made by a
competent electrician. Contact your Sears salesperson
to arrange for a professionalelectrician.
3. If metal conduit is used for the grounding conductor:
a.
B.
C.
The grounding electrode conductor shall be of copper,
aluminum, or copperclad aluminum. The material shall
be of one continuous length without a splice or joint.
Rigid metal conduit, intermediate metal conduit, or elec-
trical metallic tubing may be used for the grounding
means if conduit
or tubing is terminated
in f]ttings
approved for grounding.
Flexible metal conduit or flexible metallic tubing shall be
permitted for grounding if all the following conditions
are met:
1. The length in any ground return path does not exceed
6 feet.
2. The circuit conductors contained therein are protected
by overcurrent devices rated at 20 amperes or less.
3. The conduit
or tubing
is terminated
in fittings
approved for grounding.
For complete grounding details and all allowable exceptions,
refer to the current edition of the National Electrical Code,
NFPA 70.
4.
5.
6.
A standard _" conduit opening has been made in the water
heater junction box for the conduit connection.
Use wire nuts and connect the power supply wiring to the
wires inside the water heater's junction box.
The water heater must be electrically "grounded"
by the
installer. A green ground screw has been provided on the
water heater's junction box. Connect ground wire to this
location.
7. Replace the cabinet top, put it on the clips, almost to the
back, push down and then push back.
ELECTRIC
SUPPLY
1. Provide a way to easily shut off the electric power when work-
ing on the water heater. This could be with a circuit breaker
or fuse block in the entrance box or a separate disconnect
switch.
2. Install and connect a circuit directly from the main fuse or cir-
cuit breaker box. This circuit must be the right size and have
its own fuse or circuit breaker. Refer to the chart in the
"Product Specifications" section for the correct size wire and
fuse or circuit breaker.
WIRE CONNECTORS
GREEN GROUND
SCREW
:LAMP
13